VACStent for complex colorectal anastomotic leaks without proximal diversion: A report of two cases and practical technical insights

The VACStent combines a covered self-expanding stent with endoluminal vacuum therapy (EVT), providing drainage while maintaining a central lumen. We describe its use without proximal diversion in two complex colorectal anastomotic leaks, including a late epithelialized fistula treated with combined internal–external negative pressure, a scenario with limited evidence, and the resulting technical lessons. Two consecutive patients, the only patients treated with VACStent at our center between June and September 2025, were assessed descriptively. Both were clinically stable, without diffuse peritonitis, and at high risk from further abdominal surgery. Anatomical findings, treatment cycles, suction settings, complications, and healing were recorded. Case 1 involved a contained leak diagnosed 30 days after Hartmann reversal, treated successfully with one 7-day cycle at –100 mmHg. Case 2 involved a late fistula with an epithelialized internal opening and abdominal wall extension. Four cycles of 3, 6, 5, and 5 days were delivered over 23 elapsed days. A single initial migration was associated with vacuum loss and absent stool passage. Escalation to –300 mmHg restored suction without correcting device function; early endoscopy revealed a small mucosal ulcer. Subsequent devices at –120 mmHg maintained stool passage. External negative-pressure wound therapy was added during the last two cycles. Both patients achieved closure, with no documented recurrence at 12 months. These cases illustrate individualized VACStent treatment without diversion, including combined internal–external drainage for a chronic fistula. Practical lessons include maintaining suction during transfer, assessing stool passage alongside vacuum function, and correcting device malfunction rather than compensating with excessive suction.

Authors

Institutions

Publication Details

Journal
International Journal of Colorectal Disease
Published
2026-11-18
DOI
https://doi.org/10.1007/s00384-026-05275-8
Primary Topic
Abdominal Surgery and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

VACStent for complex colorectal anastomotic leaks without proximal diversion: A report of two cases and practical technical insights

Javier Barambio, María Luisa de Fuenmayor Valera, María García-Nebreda, A Martínez-Alcalá García et al.
5 links
International Journal of Colorectal Disease
Abdominal Surgery and Complications
article

VACStent for complex colorectal anastomotic leaks without proximal diversion: A report of two cases and practical technical insights

Javier Barambio, María Luisa de Fuenmayor Valera, María García-Nebreda, A Martínez-Alcalá García, Iris Sánchez Egido, J M Arroyo Argüelles, Mónica Prieto Doblado, Paloma Gadea Uria, Francisco Garrido Gallego, Gloria Paseiro Crespo
article en

Abstract

The VACStent combines a covered self-expanding stent with endoluminal vacuum therapy (EVT), providing drainage while maintaining a central lumen. We describe its use without proximal diversion in two complex colorectal anastomotic leaks, including a late epithelialized fistula treated with combined internal–external negative pressure, a scenario with limited evidence, and the resulting technical lessons. Two consecutive patients, the only patients treated with VACStent at our center between June and September 2025, were assessed descriptively. Both were clinically stable, without diffuse peritonitis, and at high risk from further abdominal surgery. Anatomical findings, treatment cycles, suction settings, complications, and healing were recorded. Case 1 involved a contained leak diagnosed 30 days after Hartmann reversal, treated successfully with one 7-day cycle at –100 mmHg. Case 2 involved a late fistula with an epithelialized internal opening and abdominal wall extension. Four cycles of 3, 6, 5, and 5 days were delivered over 23 elapsed days. A single initial migration was associated with vacuum loss and absent stool passage. Escalation to –300 mmHg restored suction without correcting device function; early endoscopy revealed a small mucosal ulcer. Subsequent devices at –120 mmHg maintained stool passage. External negative-pressure wound therapy was added during the last two cycles. Both patients achieved closure, with no documented recurrence at 12 months. These cases illustrate individualized VACStent treatment without diversion, including combined internal–external drainage for a chronic fistula. Practical lessons include maintaining suction during transfer, assessing stool passage alongside vacuum function, and correcting device malfunction rather than compensating with excessive suction.

International Journal of Colorectal Disease
Hospital Universitario 12 De Octubre (ES), Hospital Universitario Infanta Leonor (ES)
Good health and well-being
Abdominal Surgery and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon