Comparison of Adsorption Kinetics of Heavy Metals onto Plantain Stalk Activated Carbon

The adsorption mechanism and capacity of plantain stalk activated carbon (PSAC) in removing lead (II) ion (Pb2+) and cadmium ion (Cd2+) from aqueous solution was evaluated at different contact times. With 10 mg/L initial concentrations of Pb2+ and Cd2+, pH 6, and 2g PSAC dosage, the percentage of Pb2+ and Cd2+ removed rapidly increased to 67.34% and 59.87% within 30 min and further to 99.17% and 98.04% after 180 min, indicating that Pb2+ was more adsorbed by PSAC than Cd2+. The concentrations of the adsorbates removed after 120 min contact time was insignificant, implying that equilibrium was attained within 120 min. The experimental data were fitted to pseudo-first-order, pseudo-second-order, Elovich, and intra-particle diffusion models to determine the kinetics that best describe the mechanism of Pb2+ and Cd2+ adsorption onto PSAC. The evaluated 𝑘1 and 𝑄𝑒 with pseudo-first-order model are 0.0518 min-1 and 2.4858 mg/g for Pb2+, and 0.0506 min-1 and 4.2038 mg/g for Cd2+, respectively, whereas the evaluated 𝑘2 and 𝑄𝑒 values for pseudo-second-order model are 0.0486 g/mg.min and 1.3643 mg/g for Pb2+, and 0.0312 g/mg.min and 1.4045 mg/g for Cd2+. These indicate that the adsorption of Pb2+ onto PSAC is faster than that of Cd2+. On the other hand, the equilibrium adsorption capacity (𝑄𝑒) for Pb2+ is less than that of Cd2+, signifying that PSAC achieved a higher loading for Cd2+ than Pb2+ at equilibrium. The R2 value (0.9973) for pseudo-second-order kinetic model is higher than those from the other models, indicating that the rate control mechanism for the adsorption is chemisorption. This was further validated by the better prediction accuracy of the adsorption capacity (𝑄𝑡) by the pseudo-second-order model compare to Elovich, intra-particle diffusion and pseudo-first-order models. Hence, the mechanism of Pb2+ and Cd2+ adsorption onto PSAC is dominantly chemisorption.

Authors

Institutions

Publication Details

Journal
International Journal of Advance Engineering and Research Development
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24330097
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of Adsorption Kinetics of Heavy Metals onto Plantain Stalk Activated Carbon

V.N. Nabie, C. Ukpaka, N.D. Konee
2 links
International Journal of Advance Engineering and Research Development
Adsorption and biosorption for pollutant removal
article

Comparison of Adsorption Kinetics of Heavy Metals onto Plantain Stalk Activated Carbon

V.N. Nabie, C. Ukpaka, N.D. Konee
article en

Abstract

The adsorption mechanism and capacity of plantain stalk activated carbon (PSAC) in removing lead (II) ion (Pb2+) and cadmium ion (Cd2+) from aqueous solution was evaluated at different contact times. With 10 mg/L initial concentrations of Pb2+ and Cd2+, pH 6, and 2g PSAC dosage, the percentage of Pb2+ and Cd2+ removed rapidly increased to 67.34% and 59.87% within 30 min and further to 99.17% and 98.04% after 180 min, indicating that Pb2+ was more adsorbed by PSAC than Cd2+. The concentrations of the adsorbates removed after 120 min contact time was insignificant, implying that equilibrium was attained within 120 min. The experimental data were fitted to pseudo-first-order, pseudo-second-order, Elovich, and intra-particle diffusion models to determine the kinetics that best describe the mechanism of Pb2+ and Cd2+ adsorption onto PSAC. The evaluated 𝑘1 and 𝑄𝑒 with pseudo-first-order model are 0.0518 min-1 and 2.4858 mg/g for Pb2+, and 0.0506 min-1 and 4.2038 mg/g for Cd2+, respectively, whereas the evaluated 𝑘2 and 𝑄𝑒 values for pseudo-second-order model are 0.0486 g/mg.min and 1.3643 mg/g for Pb2+, and 0.0312 g/mg.min and 1.4045 mg/g for Cd2+. These indicate that the adsorption of Pb2+ onto PSAC is faster than that of Cd2+. On the other hand, the equilibrium adsorption capacity (𝑄𝑒) for Pb2+ is less than that of Cd2+, signifying that PSAC achieved a higher loading for Cd2+ than Pb2+ at equilibrium. The R2 value (0.9973) for pseudo-second-order kinetic model is higher than those from the other models, indicating that the rate control mechanism for the adsorption is chemisorption. This was further validated by the better prediction accuracy of the adsorption capacity (𝑄𝑡) by the pseudo-second-order model compare to Elovich, intra-particle diffusion and pseudo-first-order models. Hence, the mechanism of Pb2+ and Cd2+ adsorption onto PSAC is dominantly chemisorption.

International Journal of Advance Engineering and Research Development
Federal University of Environment and Technology (NG)
Clean water and sanitation
Adsorption and biosorption for pollutant removal
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon