Undergraduate Dental Students’ Knowledge of Instrument Reprocessing and Sterilization: An Exploratory Cross-Sectional Study

(1) Background: Appropriate dental instrument reprocessing is essential for infection prevention and patient safety. This preliminary study described undergraduate dental students’ responses to questions on instrument reprocessing, sterilization procedures, and monitoring. (2) Methods: An exploratory cross-sectional survey included 85 undergraduate dental students in academic years II–VI at one Romanian university. The 21-item questionnaire comprised four demographic items (Q1–Q4) and 17 technical multiple-choice items (Q5–Q21). Response distributions were summarized descriptively; associations were explored using chi-square or exact tests, including Monte Carlo estimation where appropriate, without adjustment for multiple comparisons. Items with ambiguous or protocol-dependent reference answers (Q9, Q10, Q12, Q13, and Q14) were interpreted descriptively rather than scored as evidence of knowledge. (3) Results: Respondents selected the questionnaire’s expected options for detergent–disinfectant solutions (89.4%), metal impression trays (84.7%), and thermosensitive trays (70.6%). For the protocol-dependent sterilization items, 85.9% selected 134 °C and 32.9% selected an 18 min exposure time; these frequencies do not establish correctness across validated cycles. Responses identifying the intended functions of the Bowie–Dick and Helix tests accounted for 50.6% and 44.7%, respectively. Exploratory associations were observed between selected questionnaire responses, but the small and unbalanced sample and multiple unadjusted tests preclude confirmatory interpretation. (4) Conclusions: This single-center preliminary investigation identified response patterns and technical topics warranting further educational assessment. The results neither establish clinical competence nor demonstrate educational progression. Future studies should use validated instruments, more representative samples, and objective competency assessments.

Authors

Institutions

Publication Details

Journal
Hygiene
Published
2026-11-18
DOI
https://doi.org/10.3390/hygiene6040087
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Undergraduate Dental Students’ Knowledge of Instrument Reprocessing and Sterilization: An Exploratory Cross-Sectional Study

Irina Grădinaru, Cătălina Iulia Săveanu, Loredana Golovcencu, Daniela Anistoroaei et al.
Hygiene
Medical Device Sterilization and Disinfection
article

Undergraduate Dental Students’ Knowledge of Instrument Reprocessing and Sterilization: An Exploratory Cross-Sectional Study

Irina Grădinaru, Cătălina Iulia Săveanu, Loredana Golovcencu, Daniela Anistoroaei, Bogdan Ioan Condrea, Ilascu Daniel, Iordache Marina Cristina Iuliana, Tesinschi Viviana-Elena, Săveanu Alexandra Ecaterina, Toma Vasilica
article en

Abstract

(1) Background: Appropriate dental instrument reprocessing is essential for infection prevention and patient safety. This preliminary study described undergraduate dental students’ responses to questions on instrument reprocessing, sterilization procedures, and monitoring. (2) Methods: An exploratory cross-sectional survey included 85 undergraduate dental students in academic years II–VI at one Romanian university. The 21-item questionnaire comprised four demographic items (Q1–Q4) and 17 technical multiple-choice items (Q5–Q21). Response distributions were summarized descriptively; associations were explored using chi-square or exact tests, including Monte Carlo estimation where appropriate, without adjustment for multiple comparisons. Items with ambiguous or protocol-dependent reference answers (Q9, Q10, Q12, Q13, and Q14) were interpreted descriptively rather than scored as evidence of knowledge. (3) Results: Respondents selected the questionnaire’s expected options for detergent–disinfectant solutions (89.4%), metal impression trays (84.7%), and thermosensitive trays (70.6%). For the protocol-dependent sterilization items, 85.9% selected 134 °C and 32.9% selected an 18 min exposure time; these frequencies do not establish correctness across validated cycles. Responses identifying the intended functions of the Bowie–Dick and Helix tests accounted for 50.6% and 44.7%, respectively. Exploratory associations were observed between selected questionnaire responses, but the small and unbalanced sample and multiple unadjusted tests preclude confirmatory interpretation. (4) Conclusions: This single-center preliminary investigation identified response patterns and technical topics warranting further educational assessment. The results neither establish clinical competence nor demonstrate educational progression. Future studies should use validated instruments, more representative samples, and objective competency assessments.

HygieneVol. 6(4)
Cliniques Universitaires Saint-Luc (BE), Grigore T. Popa University of Medicine and Pharmacy (RO), UCLouvain (BE)
Good health and well-being, Quality education
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon