Standard-Model-Extension Coefficients from the Modern Michelson-Morley Cavity Resonator Test
The Michelson-Morley experiment, repeated with modern lasers and rotating cryogenic resonators, looks for any dependence of the speed of light on direction, and this paper turns its null result into Standard-Model-Extension coefficients. The fractional shift is 1 × 10^-17, the leading coefficient comes out at 1 × 10^-17, and the ratio to the published limit is 1. Five coefficients are stated, each the shift divided by its sensitivity, with the second coefficient at 1.25 × 10^-17 and the fifth at 2.5 × 10^-17. The shift in hertz is 0.00282 at a laser frequency of 2.82 × 10^14 hertz, over an averaging time of 3 × 10^7 seconds. The result is computed from the published resonator limit and the stated sensitivities, not measured here, and it is the photon-sector anchor of the laboratory bounds.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-18
- DOI
- https://doi.org/10.5281/zenodo.24332343
- Primary Topic
- Relativity and Gravitational Theory
- Type
- article
- Field-Weighted Citation Impact
- 0.00