Efficient multi-level cooling architecture for an active vibration control unit exceeding 1120 W

Active vibration control units are crucial for ensuring accuracy in ultra-precision engineering, yet their intensive real-time computational loads generate high heat fluxes that threaten system stability. To address thermal dissipation under severe spatial constraints, this study proposes a multi-level thermal design methodology spanning system-level component matching and cold-plate optimization. A fan–radiator coupled model based on thermodynamic equilibrium was established to quantitatively match fan aerodynamic characteristics with the effective heat-transfer area of the radiator, reducing spatial redundancy under volume constraints. At the component level, an optimized cold plate incorporating a three-stage deflector and discontinuous short fins was developed to alleviate the thermo-hydraulic conflict caused by increasing fin density. Under a 360 W thermal load, the optimized design reduced the overall flow resistance by approximately 2300 Pa to 7409.84 Pa while maintaining effective heat dissipation. These results provide a systematic thermal design approach for high-power active vibration control units under restricted space.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-18
DOI
https://doi.org/10.1016/j.csite.2026.108730
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Efficient multi-level cooling architecture for an active vibration control unit exceeding 1120 W

Linyi Xiang, Zhaoyu Liu, Guanying Xing, Song Xue et al.
Case Studies in Thermal Engineering
Heat Transfer and Optimization
article

Efficient multi-level cooling architecture for an active vibration control unit exceeding 1120 W

Linyi Xiang, Zhaoyu Liu, Guanying Xing, Song Xue, Ruikang Wu, Xiaobing Luo
article en

Abstract

Active vibration control units are crucial for ensuring accuracy in ultra-precision engineering, yet their intensive real-time computational loads generate high heat fluxes that threaten system stability. To address thermal dissipation under severe spatial constraints, this study proposes a multi-level thermal design methodology spanning system-level component matching and cold-plate optimization. A fan–radiator coupled model based on thermodynamic equilibrium was established to quantitatively match fan aerodynamic characteristics with the effective heat-transfer area of the radiator, reducing spatial redundancy under volume constraints. At the component level, an optimized cold plate incorporating a three-stage deflector and discontinuous short fins was developed to alleviate the thermo-hydraulic conflict caused by increasing fin density. Under a 360 W thermal load, the optimized design reduced the overall flow resistance by approximately 2300 Pa to 7409.84 Pa while maintaining effective heat dissipation. These results provide a systematic thermal design approach for high-power active vibration control units under restricted space.

Case Studies in Thermal EngineeringVol. 88
ZTE (China) (CN), China-EU Institute for Clean and Renewable Energy (CN), Huazhong University of Science and Technology (CN)
Ministry of Education of the People's Republic of China, China Academy of Engineering Physics, Science Challenge Project
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.