Intraoperative Radiographic Visualization of the Schneiderian Membrane Using the Novel Hydraulic Contrast Lift Protocol: A Retrospective Clinical Case Series

Background: Limited intraoperative visibility during transcrestal sinus floor elevation complicates assessment of membrane elevation and possible perforation before graft placement. This retrospective case series evaluated the clinical feasibility and preliminary clinical and radiographic outcomes of the Hydraulic Contrast Lift (HCL) protocol. Materials and methods: A retrospective case series was conducted on seven patients treated with the HCL protocol. The technique uses a hydraulic delivery system to inject a radiopaque contrast medium beneath the Schneiderian membrane. Primary procedural endpoints were membrane visualization and controlled elevation without radiographic signs of perforation. Clinical endpoints included integration of the bone substitute, implant osseointegration, and implant survival. Bone height changes were assessed using preoperative cone-beam computed tomography (CBCT) and post-healing periapical radiographs or CBCT. Results: Successful intraoperative membrane visualization was achieved in all seven cases (100%), with no radiographic evidence of Schneiderian membrane perforation. The mean preoperative residual bone height was 4.5 ± 2.0 mm (range: 1.5–8 mm), and the mean postoperative bone height gain was 9.0 ± 3.3 mm (range: 4–12 mm). Five patients (71.4%) received simultaneous implant placement and two (28.6%) underwent delayed placement. All grafted areas showed radiographic continuity with adjacent bone, and all implants achieved successful osseointegration. Implant survival after implant loading (9–47 months; mean: 28.1 ± 12.8 months) was 100%. Conclusions: Within the limitations of this small retrospective case series, the HCL protocol appeared feasible, enabling intraoperative radiographic visualization of the sinus membrane and controlled elevation. No radiographic signs of membrane perforation or clinical complications were observed. Radiographic bone height gain and favorable implant outcomes were documented during follow-up. Larger prospective studies are needed to evaluate safety, reproducibility, and long-term clinical outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-11-18
DOI
https://doi.org/10.3390/jfb17110585
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Intraoperative Radiographic Visualization of the Schneiderian Membrane Using the Novel Hydraulic Contrast Lift Protocol: A Retrospective Clinical Case Series

Didem Dagdeviren, Mohamed A. M. Youssef
Journal of Functional Biomaterials
Dental Implant Techniques and Outcomes
article

Intraoperative Radiographic Visualization of the Schneiderian Membrane Using the Novel Hydraulic Contrast Lift Protocol: A Retrospective Clinical Case Series

Didem Dagdeviren, Mohamed A. M. Youssef
article en

Abstract

Background: Limited intraoperative visibility during transcrestal sinus floor elevation complicates assessment of membrane elevation and possible perforation before graft placement. This retrospective case series evaluated the clinical feasibility and preliminary clinical and radiographic outcomes of the Hydraulic Contrast Lift (HCL) protocol. Materials and methods: A retrospective case series was conducted on seven patients treated with the HCL protocol. The technique uses a hydraulic delivery system to inject a radiopaque contrast medium beneath the Schneiderian membrane. Primary procedural endpoints were membrane visualization and controlled elevation without radiographic signs of perforation. Clinical endpoints included integration of the bone substitute, implant osseointegration, and implant survival. Bone height changes were assessed using preoperative cone-beam computed tomography (CBCT) and post-healing periapical radiographs or CBCT. Results: Successful intraoperative membrane visualization was achieved in all seven cases (100%), with no radiographic evidence of Schneiderian membrane perforation. The mean preoperative residual bone height was 4.5 ± 2.0 mm (range: 1.5–8 mm), and the mean postoperative bone height gain was 9.0 ± 3.3 mm (range: 4–12 mm). Five patients (71.4%) received simultaneous implant placement and two (28.6%) underwent delayed placement. All grafted areas showed radiographic continuity with adjacent bone, and all implants achieved successful osseointegration. Implant survival after implant loading (9–47 months; mean: 28.1 ± 12.8 months) was 100%. Conclusions: Within the limitations of this small retrospective case series, the HCL protocol appeared feasible, enabling intraoperative radiographic visualization of the sinus membrane and controlled elevation. No radiographic signs of membrane perforation or clinical complications were observed. Radiographic bone height gain and favorable implant outcomes were documented during follow-up. Larger prospective studies are needed to evaluate safety, reproducibility, and long-term clinical outcomes.

Journal of Functional BiomaterialsVol. 17(11)
McGill University (CA)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon