Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis

BACKGROUND: The European Society of Cardiology rapid rule-out and rule-in protocols using hs-cTns (high-sensitivity cardiac troponins) with blood collection at 0 and 1 hour (0/1 hour), 0 and 2 hours (0/2 hours), and 0 and 3 hours (0/3 hours) are accurate and widely used for evaluating non-ST-segment-elevation myocardial infarction. This network meta-analysis aimed to identify the best performing hs-cTn assay. METHODS: We conducted database searches up to January 15, 2026, a dual screening and eligibility assessment, independent data extraction and risk of bias assessment, a network meta-analysis of diagnostic accuracy, and assessment of the certainty of evidence. Only full-paired diagnostic accuracy studies conducted in the emergency department were included. RESULTS: Ten prospective studies (15 publications) comparing 10 assays using the 0-/1-hour algorithm (n=8769), 0-/2-hour algorithm (n=1881), and 0-/3-hour algorithm (n=1236) were included. Comparisons between newer and conventional assays largely stemmed from a single-source study. Across all assays, the European Society of Cardiology 0-/1-hour algorithm demonstrated high sensitivity (summary point estimate range: 97.8%-99.8%). Furthermore, it maintained high specificity (89.8%-98.1%), with no assay showing clear superiority. The summary sensitivity and specificity did not show significant differences across assays after adjusting for biases because of imperfect reference standards. Comparative data in the European Society of Cardiology 0-/2-hour and 0-/3-hour algorithms were limited. CONCLUSIONS: Evidence remains insufficient to establish the superiority of any specific hs-cTn assay within the European Society of Cardiology 0-/1-hour algorithm. Although practical considerations may currently guide selection, continued validation of newer assays remains necessary.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-11-18
DOI
https://doi.org/10.1161/jaha.125.047758
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis

Kristin Moberg Aakre, Morwenna Rogers, Pedro López‐Ayala, Teruhiko Terasawa et al.
1 links
Journal of the American Heart Association
Acute Myocardial Infarction Research
article

Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis

Kristin Moberg Aakre, Morwenna Rogers, Pedro López‐Ayala, Teruhiko Terasawa, Mitsunaga Iwata, Luca Koechlin, Christopher Hyde, Hirotaka Ohtake, Jasper Boeddinghaus, Zhivko Zhelev, Jaime Peters, Ingar Ziad Restan, Christian Eugen Mueller, Viola I L Thulin
article en

Abstract

BACKGROUND: The European Society of Cardiology rapid rule-out and rule-in protocols using hs-cTns (high-sensitivity cardiac troponins) with blood collection at 0 and 1 hour (0/1 hour), 0 and 2 hours (0/2 hours), and 0 and 3 hours (0/3 hours) are accurate and widely used for evaluating non-ST-segment-elevation myocardial infarction. This network meta-analysis aimed to identify the best performing hs-cTn assay. METHODS: We conducted database searches up to January 15, 2026, a dual screening and eligibility assessment, independent data extraction and risk of bias assessment, a network meta-analysis of diagnostic accuracy, and assessment of the certainty of evidence. Only full-paired diagnostic accuracy studies conducted in the emergency department were included. RESULTS: Ten prospective studies (15 publications) comparing 10 assays using the 0-/1-hour algorithm (n=8769), 0-/2-hour algorithm (n=1881), and 0-/3-hour algorithm (n=1236) were included. Comparisons between newer and conventional assays largely stemmed from a single-source study. Across all assays, the European Society of Cardiology 0-/1-hour algorithm demonstrated high sensitivity (summary point estimate range: 97.8%-99.8%). Furthermore, it maintained high specificity (89.8%-98.1%), with no assay showing clear superiority. The summary sensitivity and specificity did not show significant differences across assays after adjusting for biases because of imperfect reference standards. Comparative data in the European Society of Cardiology 0-/2-hour and 0-/3-hour algorithms were limited. CONCLUSIONS: Evidence remains insufficient to establish the superiority of any specific hs-cTn assay within the European Society of Cardiology 0-/1-hour algorithm. Although practical considerations may currently guide selection, continued validation of newer assays remains necessary.

Journal of the American Heart Association
Fujita Health University (JP), University of Exeter (GB), Stavanger University Hospital (NO), Haukeland University Hospital (NO), University Hospital of Basel (CH), University Hospital of Zurich (CH), University of Bergen (NO)
Good health and well-being
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon