AI-Based Prediction of Total Porosity Volume Fraction from 3D CT Volumes: A Volumetric Regression Approach

Computed Tomography (CT) is a premier non-destructive testing (NDT) modality used for inspecting internal defects, particularly porosity in additive manufacturing and metal castings. The standard industry workflow relies on voxel-wise image segmentation (e.g., Otsu thresholding) to separate void spaces from the solid matrix before calculating the total Porosity Volume Fraction (PVF). However, this segmentation step is highly brittle under severe measurement noise and artifacts, leading to catastrophic miscalculations. In this paper, we propose a direct deep-learning regression approach using a 3D Convolutional Neural Network (CNN) equipped with Global Average Pooling (GAP) to predict scalar PVF directly from noisy 3D CT volumes, bypassing segmentation entirely. To validate this hypothesis, we engineered a rigorous synthetic 3D CT dataset containing 500 procedural phantoms with precisely controlled spherical pores and uniformly distributed PVF ranging from 0.1% to 15%. We degraded these volumes with varying levels of Gaussian noise (10 dB, 20 dB, and 30 dB SNR). The 3D CNN was evaluated against classical Otsu thresholding and a Random Forest (RF) machine learning baseline utilizing global intensity statistics. Our results demonstrate that the 3D CNN is exceptionally robust, maintaining a low Mean Absolute Error (MAE) of 0.363 percentage points even under extreme 10 dB noise, where Otsu thresholding catastrophically collapses (MAE of 11.51 pp). Unexpectedly, the RF baseline achieved the lowest overall MAE (0.088 pp). Through a rigorous evidence audit and domain-shift experiment involving a simulated beam-hardening cupping artifact, we dissect this phenomenon, revealing that the RF's superiority is a statistical artifact of the synthetic data's homogenous matrix assumption. This research highlights the viability of segmentation-free volumetric regression for NDT while providing a critical warning regarding 'shortcut learning' in synthetic physics datasets.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11733357/v1
Primary Topic
Advanced X-ray and CT Imaging
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

AI-Based Prediction of Total Porosity Volume Fraction from 3D CT Volumes: A Volumetric Regression Approach

Mayank Goswami, Bhanu Prakash Godara
5 links
Research Square
Advanced X-ray and CT Imaging
preprint

AI-Based Prediction of Total Porosity Volume Fraction from 3D CT Volumes: A Volumetric Regression Approach

Mayank Goswami, Bhanu Prakash Godara
preprint en

Abstract

Computed Tomography (CT) is a premier non-destructive testing (NDT) modality used for inspecting internal defects, particularly porosity in additive manufacturing and metal castings. The standard industry workflow relies on voxel-wise image segmentation (e.g., Otsu thresholding) to separate void spaces from the solid matrix before calculating the total Porosity Volume Fraction (PVF). However, this segmentation step is highly brittle under severe measurement noise and artifacts, leading to catastrophic miscalculations. In this paper, we propose a direct deep-learning regression approach using a 3D Convolutional Neural Network (CNN) equipped with Global Average Pooling (GAP) to predict scalar PVF directly from noisy 3D CT volumes, bypassing segmentation entirely. To validate this hypothesis, we engineered a rigorous synthetic 3D CT dataset containing 500 procedural phantoms with precisely controlled spherical pores and uniformly distributed PVF ranging from 0.1% to 15%. We degraded these volumes with varying levels of Gaussian noise (10 dB, 20 dB, and 30 dB SNR). The 3D CNN was evaluated against classical Otsu thresholding and a Random Forest (RF) machine learning baseline utilizing global intensity statistics. Our results demonstrate that the 3D CNN is exceptionally robust, maintaining a low Mean Absolute Error (MAE) of 0.363 percentage points even under extreme 10 dB noise, where Otsu thresholding catastrophically collapses (MAE of 11.51 pp). Unexpectedly, the RF baseline achieved the lowest overall MAE (0.088 pp). Through a rigorous evidence audit and domain-shift experiment involving a simulated beam-hardening cupping artifact, we dissect this phenomenon, revealing that the RF's superiority is a statistical artifact of the synthetic data's homogenous matrix assumption. This research highlights the viability of segmentation-free volumetric regression for NDT while providing a critical warning regarding 'shortcut learning' in synthetic physics datasets.

Research Square
Indian Institute of Technology Roorkee (IN)
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon