Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids

Converter current and power limits alter the fault voltage–current relationship in microgrids. This paper coordinates a bounded voltage-dependent pickup characteristic with mode-specific setting groups for passive laterals and their immediate backups. A common balanced static source model is used for pre-fault, fault, and post-clearance calculations. An outer differential-evolution search determines pickup parameters, monotone propagation solves the fixed-pickup timing inequalities, and an independent linear program checks selected timing solutions. The 10 kV, 14-bus study includes 450 setting faults and 210 validation faults, with 280 prescribed validation events. Under the same two-group configuration and a 40 ms trip-command floor, voltage supervision with separate joint retuning reduces islanded target-pair TROT by 30.11% over 30 bus-14 faults and by 10.30% over all 70 bus-14 target faults relative to IDMT. The mean main-protection trip-command delay over all 210 validation faults decreases from 49.743 to 48.584 ms (2.33%). All prescribed validation events pass the proposed-setting checks, with a minimum worst-case CTI of 300.078 ms and a minimum error-adjusted normal pickup margin of 1.25101. Nine design-parameter combinations use twenty seeds per group and the same selection rule as the principal benchmark. The grouping provides mode-specific setting management; no incremental clustering benefit or quantified single-to-two-group improvement is established. Conclusions apply to the finite balanced static libraries, fixed source ratings and internal topology, and correct pre-fault group selection.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-18
DOI
https://doi.org/10.3390/en19225569
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids

Zhang Panmei, Zhidong Wang, Zhanhong Liang, Zifan Zhang et al.
1 links
Energies
Power Systems Fault Detection
article

Voltage-Supervised Inverse-Time Overcurrent Protection Coordination with Scenario-Based Setting Groups for Inverter-Dominated Microgrids

Zhang Panmei, Zhidong Wang, Zhanhong Liang, Zifan Zhang, Hanlin Yu
article en

Abstract

Converter current and power limits alter the fault voltage–current relationship in microgrids. This paper coordinates a bounded voltage-dependent pickup characteristic with mode-specific setting groups for passive laterals and their immediate backups. A common balanced static source model is used for pre-fault, fault, and post-clearance calculations. An outer differential-evolution search determines pickup parameters, monotone propagation solves the fixed-pickup timing inequalities, and an independent linear program checks selected timing solutions. The 10 kV, 14-bus study includes 450 setting faults and 210 validation faults, with 280 prescribed validation events. Under the same two-group configuration and a 40 ms trip-command floor, voltage supervision with separate joint retuning reduces islanded target-pair TROT by 30.11% over 30 bus-14 faults and by 10.30% over all 70 bus-14 target faults relative to IDMT. The mean main-protection trip-command delay over all 210 validation faults decreases from 49.743 to 48.584 ms (2.33%). All prescribed validation events pass the proposed-setting checks, with a minimum worst-case CTI of 300.078 ms and a minimum error-adjusted normal pickup margin of 1.25101. Nine design-parameter combinations use twenty seeds per group and the same selection rule as the principal benchmark. The grouping provides mode-specific setting management; no incremental clustering benefit or quantified single-to-two-group improvement is established. Conclusions apply to the finite balanced static libraries, fixed source ratings and internal topology, and correct pre-fault group selection.

EnergiesVol. 19(22)
PowerELab (China) (CN), Guangzhou City University of Technology (CN), South China University of Technology (CN)
Affordable and clean energy, Industry, innovation and infrastructure
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon