Radiotherapy Vault Shielding Design Using Geant4
Radiotherapy facilities require effective structural shielding to protect patients, radiation workers, and members of the public from ionizing radiation. Conventional shielding design relies primarily on analytical calculations, which may not fully represent complex radiation transport and geometrical configurations. This study presents an innovative approach to optimizing radiotherapy vault shielding using the Geant4 Monte Carlo simulation toolkit. A three-dimensional radiotherapy vault model was developed to simulate radiation transport, particle interactions, and attenuation through concrete barriers. Primary and secondary shielding configurations were investigated to evaluate their effectiveness in reducing radiation exposure. The simulation framework was used to assess barrier thickness and radiation distribution at selected locations surrounding the treatment room. Preliminary results indicated that optimized primary and secondary barrier thicknesses of 70 cm and 50 cm, respectively, achieved a 14.1% reduction in the evaluated radiation level. This approach demonstrates the potential of Monte Carlo simulation to support safer, more efficient, and cost-effective radiotherapy vault shielding design.
Authors
- Siti Amira Othman (ORCID: https://orcid.org/0000-0003-1772-9167)
- Ngoh Ea Son
Publication Details
- Journal
- Innovation Series Quarterly
- Published
- 2026-11-16
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00