DMSA-KANet: Improving Breast Cancer Segmentation in Mammography through Deep Supervision Multi-scale Attention and Kolmogorov-Arnold Networks

Breast cancer segmentation in mammography remains challenging owing to the small lesion size, low contrast, and overlapping fibroglandular tissue.This study proposes the Deep Supervision Multi-Scale Attention Kolmogorov-Arnold Network (DMSA-KANet), a hybrid architecture that combines an EfficientNetB4 encoder with a high-resolution path, a multi-scale attention bottleneck refined sequentially by Kolmogorov-Arnold Network (KAN) layers, a Vision Transformer, and a KAN-based Convolutional Block Attention Module (KAN-CBAM), and a decoder with KAN-gated skip connections and deep supervision.The model was evaluated on the low-energy images of CDD-CESM (650 images, 282 patients) and on the mass subset of CBIS-DDSM (1,592 images, 892 patients) with patientlevel five-fold cross-validation, in which checkpoint and threshold selection used only validation patients drawn from the training folds, and it was compared with baselines retrained under the same folds, loss, augmentation, epoch budget, and selection rules.Under this protocol DMSA-KANet did not outperform the baselines: it achieved a Dice of 43.97 ± 9.11% on CDD-CESM, the lowest of the seven models, compared with 51.02 ± 3.94% for U-Net and 51.50 ± 3.37% for TransUNet, and 39.98 ± 8.40% on CBIS-DDSM (44.93 ± 1.96% with its learning rates re-selected within the training patients of each fold), compared with 46.80 ± 5.86% for U-Net and 51.06 ± 4.26% for TransUNet, with larger variation across folds than any successfully trained baseline.The gap was associated with fold-level over-segmentation failures and unstable decision thresholds.These results describe retrospective technical performance on two public datasets and indicate that the added architectural complexity did not yield more accurate lesion segmentation under patient-level evaluation.The study provides a reproducible patient-level benchmark for CDD-CESM and CBIS-DDSM, with all fold assignments, code, and per-fold results publicly released.

Authors

Institutions

Publication Details

Journal
International journal of intelligent engineering and systems
Published
2026-11-17
DOI
https://doi.org/10.22266/ijies2026.1231.57
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

DMSA-KANet: Improving Breast Cancer Segmentation in Mammography through Deep Supervision Multi-scale Attention and Kolmogorov-Arnold Networks

Andrew Prasetyo, Mauridhi Hery Purnomo, Dyah Titisari, Eko Mulyanto Yuniarno et al.
2 links
International journal of intelligent engineering and systems
AI in cancer detection
article

DMSA-KANet: Improving Breast Cancer Segmentation in Mammography through Deep Supervision Multi-scale Attention and Kolmogorov-Arnold Networks

Andrew Prasetyo, Mauridhi Hery Purnomo, Dyah Titisari, Eko Mulyanto Yuniarno, I Ketut Eddy Purnama
article en

Abstract

Breast cancer segmentation in mammography remains challenging owing to the small lesion size, low contrast, and overlapping fibroglandular tissue.This study proposes the Deep Supervision Multi-Scale Attention Kolmogorov-Arnold Network (DMSA-KANet), a hybrid architecture that combines an EfficientNetB4 encoder with a high-resolution path, a multi-scale attention bottleneck refined sequentially by Kolmogorov-Arnold Network (KAN) layers, a Vision Transformer, and a KAN-based Convolutional Block Attention Module (KAN-CBAM), and a decoder with KAN-gated skip connections and deep supervision.The model was evaluated on the low-energy images of CDD-CESM (650 images, 282 patients) and on the mass subset of CBIS-DDSM (1,592 images, 892 patients) with patientlevel five-fold cross-validation, in which checkpoint and threshold selection used only validation patients drawn from the training folds, and it was compared with baselines retrained under the same folds, loss, augmentation, epoch budget, and selection rules.Under this protocol DMSA-KANet did not outperform the baselines: it achieved a Dice of 43.97 ± 9.11% on CDD-CESM, the lowest of the seven models, compared with 51.02 ± 3.94% for U-Net and 51.50 ± 3.37% for TransUNet, and 39.98 ± 8.40% on CBIS-DDSM (44.93 ± 1.96% with its learning rates re-selected within the training patients of each fold), compared with 46.80 ± 5.86% for U-Net and 51.06 ± 4.26% for TransUNet, with larger variation across folds than any successfully trained baseline.The gap was associated with fold-level over-segmentation failures and unstable decision thresholds.These results describe retrospective technical performance on two public datasets and indicate that the added architectural complexity did not yield more accurate lesion segmentation under patient-level evaluation.The study provides a reproducible patient-level benchmark for CDD-CESM and CBIS-DDSM, with all fold assignments, code, and per-fold results publicly released.

International journal of intelligent engineering and systemsVol. 19(12)
Sepuluh Nopember Institute of Technology (ID), Kementerian Kesehatan Republik Indonesia (ID), Poltekkes Kemenkes Surabaya (ID)
Ministry of Health of the Republic of Indonesia
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon