Quantification of Spin Fluctuations during Stem Cell Differentiation Using Diamond Nanopillars

Quantitative detection of radical–associated magnetic activity in living cells remains challenging because variations between quantum sensors complicate direct comparisons of intracellular environments. Here, we demonstrate a label-free quantum sensing platform based on substrate–fixed diamond nanopillars containing individually addressable nitrogen-vacancy (NV) centers. The fixed architecture enables one–to–one measurements using identical NV sensors in the presence and absence of cells, minimizing sensor–to–sensor variability and allowing reliable assessment of cellular contributions to spin decoherence. Cellular compatibility assays supported preserved metabolic activity, DNA synthesis, and membrane integrity without detectable apoptotic activation. Intracellular NV centers retained approximately 10% optically detected magnetic resonance contrast, 20% Rabi contrast, and a Hahn–echo coherence time T 2 of approximately 3 µs. Carr–Purcell–Meiboom–Gill dynamical decoupling extended intracellular T 2 to 25.8 ± 4.90 µs. We applied this platform to embryonic stem (ES) cells undergoing doxycycline-induced differentiation toward the trophectoderm lineage. Identical NV sensors exhibited consistent coherence recovery following removal of differentiation–induced cells, whereas undifferentiated controls showed no systematic recovery. Calibration using the stable radical TEMPOL, supported by magnetic-noise modeling and kinetic Monte Carlo simulations, enabled numerical evaluation of local magnetic responses as model-dependent TEMPOL–equivalent spin densities of 0.084–0.567 spins/nm 3 across different sensing sites. These findings establish a quantitative approach to investigating intracellular physicochemical changes during stem-cell differentiation and demonstrate the potential of quantum sensing to study biological processes relevant to tissue development and regenerative medicine.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-17
DOI
https://doi.org/10.64898/2026.11.16.767033
Primary Topic
Diamond and Carbon-based Materials Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Quantification of Spin Fluctuations during Stem Cell Differentiation Using Diamond Nanopillars

Hitoshi Ishiwata, Hitoshi Niwa, Yoko Shigeno, Abdul Nasir
3 links
bioRxiv (Cold Spring Harbor Laboratory)
Diamond and Carbon-based Materials Research
preprint

Quantification of Spin Fluctuations during Stem Cell Differentiation Using Diamond Nanopillars

Hitoshi Ishiwata, Hitoshi Niwa, Yoko Shigeno, Abdul Nasir
preprint en

Abstract

Quantitative detection of radical–associated magnetic activity in living cells remains challenging because variations between quantum sensors complicate direct comparisons of intracellular environments. Here, we demonstrate a label-free quantum sensing platform based on substrate–fixed diamond nanopillars containing individually addressable nitrogen-vacancy (NV) centers. The fixed architecture enables one–to–one measurements using identical NV sensors in the presence and absence of cells, minimizing sensor–to–sensor variability and allowing reliable assessment of cellular contributions to spin decoherence. Cellular compatibility assays supported preserved metabolic activity, DNA synthesis, and membrane integrity without detectable apoptotic activation. Intracellular NV centers retained approximately 10% optically detected magnetic resonance contrast, 20% Rabi contrast, and a Hahn–echo coherence time T 2 of approximately 3 µs. Carr–Purcell–Meiboom–Gill dynamical decoupling extended intracellular T 2 to 25.8 ± 4.90 µs. We applied this platform to embryonic stem (ES) cells undergoing doxycycline-induced differentiation toward the trophectoderm lineage. Identical NV sensors exhibited consistent coherence recovery following removal of differentiation–induced cells, whereas undifferentiated controls showed no systematic recovery. Calibration using the stable radical TEMPOL, supported by magnetic-noise modeling and kinetic Monte Carlo simulations, enabled numerical evaluation of local magnetic responses as model-dependent TEMPOL–equivalent spin densities of 0.084–0.567 spins/nm 3 across different sensing sites. These findings establish a quantitative approach to investigating intracellular physicochemical changes during stem-cell differentiation and demonstrate the potential of quantum sensing to study biological processes relevant to tissue development and regenerative medicine.

bioRxiv (Cold Spring Harbor Laboratory)
Chiba University (JP), National Institutes for Quantum Science and Technology (JP), Institute of Molecular Embryology and Genetics, Kumamoto University (JP), Institute for Quantum Life Science (JP), Kumamoto University (JP)
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon