Development of a camera-based refractive error image simulation dataset and mobile application: a proof-of-concept study

Conventional descriptions and diagrams of refractive error may not convey how lower-order optical defocus changes scene appearance. Existing observer-based, source-based, adaptive-optics, software, and extended-reality simulations differ in optical fidelity, accessibility, and intended use. We developed a camera-based image dataset and a mobile application as an illustrative proof of concept for refractive-blur visualization. All 2,008 refractive-condition images were individually photographed in May 2024 using a Canon EOS R10 camera (18 mm, f/5) with an RF-S18-45 mm F4.5-6.3 IS STM lens, and supplementary spherical and cylindrical trial lenses. Conditions comprised 40 spherical powers (± 0.25 to ± 5.00 D in 0.25-D steps) and 48 cylinder conditions (− 0.25 to − 3.00 D in 0.25-D steps at 0°, 45°, 90°, and 135°), alone and in combination. The images were organized for offline retrieval in an iOS/iPadOS application. The dataset comprised 2,008 refractive-condition images: 1,920 combined spherocylindrical images (40 × 48), 40 sphere-only images, and 48 cylinder-only images. The application, iVision Refractive Demo, displays the stored image corresponding to the selected lower-order refractive settings. No psychophysical, diagnostic-accuracy, usability, or patient-outcome validation was performed. This study created a 2,008-image camera-based refractive-blur dataset and an accompanying mobile application. The output should be regarded as an unvalidated illustrative proof of concept, not as a patient-specific prediction of perceived vision or a simulator of multifocal or extended-depth-of-focus intraocular-lens performance. Optical bench testing, reproducibility assessment, observer studies, and clinical usability evaluation are required before clinical effectiveness can be claimed.

Authors

Institutions

Publication Details

Journal
BMC Ophthalmology
Published
2026-11-17
DOI
https://doi.org/10.1186/s12886-026-05506-0
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development of a camera-based refractive error image simulation dataset and mobile application: a proof-of-concept study

Thanaporn Wiriyabanditkul, Somtaporn Ueathaweephol, Thanapong Somkijrungroj, Varin Dejgambhir
BMC Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Development of a camera-based refractive error image simulation dataset and mobile application: a proof-of-concept study

Thanaporn Wiriyabanditkul, Somtaporn Ueathaweephol, Thanapong Somkijrungroj, Varin Dejgambhir
article en

Abstract

Conventional descriptions and diagrams of refractive error may not convey how lower-order optical defocus changes scene appearance. Existing observer-based, source-based, adaptive-optics, software, and extended-reality simulations differ in optical fidelity, accessibility, and intended use. We developed a camera-based image dataset and a mobile application as an illustrative proof of concept for refractive-blur visualization. All 2,008 refractive-condition images were individually photographed in May 2024 using a Canon EOS R10 camera (18 mm, f/5) with an RF-S18-45 mm F4.5-6.3 IS STM lens, and supplementary spherical and cylindrical trial lenses. Conditions comprised 40 spherical powers (± 0.25 to ± 5.00 D in 0.25-D steps) and 48 cylinder conditions (− 0.25 to − 3.00 D in 0.25-D steps at 0°, 45°, 90°, and 135°), alone and in combination. The images were organized for offline retrieval in an iOS/iPadOS application. The dataset comprised 2,008 refractive-condition images: 1,920 combined spherocylindrical images (40 × 48), 40 sphere-only images, and 48 cylinder-only images. The application, iVision Refractive Demo, displays the stored image corresponding to the selected lower-order refractive settings. No psychophysical, diagnostic-accuracy, usability, or patient-outcome validation was performed. This study created a 2,008-image camera-based refractive-blur dataset and an accompanying mobile application. The output should be regarded as an unvalidated illustrative proof of concept, not as a patient-specific prediction of perceived vision or a simulator of multifocal or extended-depth-of-focus intraocular-lens performance. Optical bench testing, reproducibility assessment, observer studies, and clinical usability evaluation are required before clinical effectiveness can be claimed.

BMC Ophthalmology
Thai Red Cross Society (TH), Chulalongkorn University (TH), King Chulalongkorn Memorial Hospital (TH), Bhumibol Adulyadej Hospital (TH)
Good health and well-being
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon