A coordinate-consistency audit for triaxial vibration diagnosis
Accuracy reported in one sensor basis can hide a diagnosis that changes when the same record is re-expressed. We introduce an output-level O ( 3 ) audit that separates coordinate consistency, cross-band information retention, and physical-unit utility. MUET provides the primary audit; MCC5 checks operating profiles at two sensor locations on one rig, using the same 240 files. Across the fixed 1072-view tensor orbit, ordered coordinates had mean worst-case probability drift 0.5180, against 7.68 × 10 − 16 (maximum 1.94 × 10 − 15 ) for the proposed signature. Both collision witnesses passed. With six matched-severity blocks, MUET utility remained inconclusive (balanced accuracy 0.4167, 95% cluster interval 0.1667–0.6667). MCC5 exposed profile-specific utility shortfalls. The audit exposes a failure mode that accuracy cannot see and tells deployment teams whether to correct coordinates or gather stronger diagnostic evidence.
Authors
- Zongyuan Yang (ORCID: https://orcid.org/0009-0003-3798-3565)
Institutions
- Kunming University of Science and Technology (CN)
Publication Details
- Journal
- Journal of Vibration and Control
- Published
- 2026-11-16
- DOI
- https://doi.org/10.1177/10775463261505814
- Primary Topic
- Machine Fault Diagnosis Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00