A coordinate-consistency audit for triaxial vibration diagnosis

Accuracy reported in one sensor basis can hide a diagnosis that changes when the same record is re-expressed. We introduce an output-level O ( 3 ) audit that separates coordinate consistency, cross-band information retention, and physical-unit utility. MUET provides the primary audit; MCC5 checks operating profiles at two sensor locations on one rig, using the same 240 files. Across the fixed 1072-view tensor orbit, ordered coordinates had mean worst-case probability drift 0.5180, against 7.68 × 10 − 16 (maximum 1.94 × 10 − 15 ) for the proposed signature. Both collision witnesses passed. With six matched-severity blocks, MUET utility remained inconclusive (balanced accuracy 0.4167, 95% cluster interval 0.1667–0.6667). MCC5 exposed profile-specific utility shortfalls. The audit exposes a failure mode that accuracy cannot see and tells deployment teams whether to correct coordinates or gather stronger diagnostic evidence.

Authors

Institutions

Publication Details

Journal
Journal of Vibration and Control
Published
2026-11-16
DOI
https://doi.org/10.1177/10775463261505814
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A coordinate-consistency audit for triaxial vibration diagnosis

Zongyuan Yang
Journal of Vibration and Control
Machine Fault Diagnosis Techniques
article

A coordinate-consistency audit for triaxial vibration diagnosis

Zongyuan Yang
article en

Abstract

Accuracy reported in one sensor basis can hide a diagnosis that changes when the same record is re-expressed. We introduce an output-level O ( 3 ) audit that separates coordinate consistency, cross-band information retention, and physical-unit utility. MUET provides the primary audit; MCC5 checks operating profiles at two sensor locations on one rig, using the same 240 files. Across the fixed 1072-view tensor orbit, ordered coordinates had mean worst-case probability drift 0.5180, against 7.68 × 10 − 16 (maximum 1.94 × 10 − 15 ) for the proposed signature. Both collision witnesses passed. With six matched-severity blocks, MUET utility remained inconclusive (balanced accuracy 0.4167, 95% cluster interval 0.1667–0.6667). MCC5 exposed profile-specific utility shortfalls. The audit exposes a failure mode that accuracy cannot see and tells deployment teams whether to correct coordinates or gather stronger diagnostic evidence.

Journal of Vibration and Control
Kunming University of Science and Technology (CN)
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon