How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors

The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient $κ$ ($κ=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $κ$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about $κ$ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is $κ_{obs}=1-α(1-κ_{pick})$, with a pick-off share $α$ of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply $κ_{pick}$ = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With $^{18}$F and an eight-module ring, $κ$ can be measured to $\pm0.01$ in a 10-mm tumour, but separating tissues by $κ$ alone requires 6-74 times more decays than are available.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-16
DOI
https://doi.org/10.48550/arxiv.2611.21022
Primary Topic
Medical Imaging Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors

Ruonan Wang, Haitao Zhou, Zhifang Wu, Jianyong Hu et al.
arXiv (Cornell University)
Medical Imaging Techniques and Applications
preprint

How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors

Ruonan Wang, Haitao Zhou, Zhifang Wu, Jianyong Hu, Sijin Li
preprint en

Abstract

The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient $κ$ ($κ=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $κ$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about $κ$ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is $κ_{obs}=1-α(1-κ_{pick})$, with a pick-off share $α$ of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply $κ_{pick}$ = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With $^{18}$F and an eight-module ring, $κ$ can be measured to $\pm0.01$ in a 10-mm tumour, but separating tissues by $κ$ alone requires 6-74 times more decays than are available.

arXiv (Cornell University)
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon