Computational modelling of peri-implant bone remodelling: a sensitivity analysis

Peri-implant bone adaptation is governed by the mechanical environment induced after dental implant placement and is clinically associated with both bone formation and resorption, particularly in the crestal region. This study aimed to investigate patient-specific peri‑implant trabecular bone adaptation using a voxel-based micro-finite-element framework with osteocyte-driven remodelling. Human mandibular bone segments reconstructed from micro-computed tomography (micro-CT) data were converted into voxel-based finite element models. Bone adaptation was driven by an osteocyte-based strain energy density (SED) stimulus and described using an iterative density evolution algorithm. Model parameters were determined based on a sensitivity analysis and applied to five bone segments. Simulations were performed to evaluate region-specific remodelling behaviour and convergence characteristics. One segment exhibited excessive peri‑implant resorption leading to complete loss of bone–implant contact and numerical instability of the finite element solution. The remaining four bone segments converged according to the predefined convergence criteria. Pronounced crestal bone resorption was observed in three other segments, while the last segment exhibited a predominantly stable response without noticeable crestal resorption. Results demonstrated variability in adaptation behaviour across specimens. The proposed framework enables microstructurally resolved simulation of peri‑implant bone adaptation and reproduces crestal bone resorption, driven by local mechanical stimulus distribution, using the calibrated model parameters. However, since crestal resorption was considered during parameter calibration, its occurrence cannot be regarded as independent validation of the model. The findings highlight the role of trabecular architecture in governing heterogeneous remodelling responses around dental implants.

Authors

Institutions

Publication Details

Journal
International Journal of Engineering Science
Published
2026-11-17
DOI
https://doi.org/10.1016/j.ijengsci.2026.104730
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Computational modelling of peri-implant bone remodelling: a sensitivity analysis

V. Fuis, Petr Marcián, Olga Košková, Marek Joukal et al.
International Journal of Engineering Science
Dental Implant Techniques and Outcomes
article

Computational modelling of peri-implant bone remodelling: a sensitivity analysis

V. Fuis, Petr Marcián, Olga Košková, Marek Joukal, Votava Tomáš, Wolff Jan
article en

Abstract

Peri-implant bone adaptation is governed by the mechanical environment induced after dental implant placement and is clinically associated with both bone formation and resorption, particularly in the crestal region. This study aimed to investigate patient-specific peri‑implant trabecular bone adaptation using a voxel-based micro-finite-element framework with osteocyte-driven remodelling. Human mandibular bone segments reconstructed from micro-computed tomography (micro-CT) data were converted into voxel-based finite element models. Bone adaptation was driven by an osteocyte-based strain energy density (SED) stimulus and described using an iterative density evolution algorithm. Model parameters were determined based on a sensitivity analysis and applied to five bone segments. Simulations were performed to evaluate region-specific remodelling behaviour and convergence characteristics. One segment exhibited excessive peri‑implant resorption leading to complete loss of bone–implant contact and numerical instability of the finite element solution. The remaining four bone segments converged according to the predefined convergence criteria. Pronounced crestal bone resorption was observed in three other segments, while the last segment exhibited a predominantly stable response without noticeable crestal resorption. Results demonstrated variability in adaptation behaviour across specimens. The proposed framework enables microstructurally resolved simulation of peri‑implant bone adaptation and reproduces crestal bone resorption, driven by local mechanical stimulus distribution, using the calibrated model parameters. However, since crestal resorption was considered during parameter calibration, its occurrence cannot be regarded as independent validation of the model. The findings highlight the role of trabecular architecture in governing heterogeneous remodelling responses around dental implants.

International Journal of Engineering ScienceVol. 231
Masaryk University (CZ), University Hospital Brno (CZ), University Hospital Schleswig-Holstein (DE), Fraunhofer-Einrichtung für Individualisierte Medizintechnik (DE), Czech Academy of Sciences, Institute of Thermomechanics (CZ), Brno University of Technology (CZ), University of Lübeck (DE)
Ministerstvo Školství, Mládeže a Tělovýchovy, Ministerstvo Zdravotnictví Ceské Republiky, Technische Universität Wien, Ústav termomechaniky, Akademie Věd České Republiky
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon