Respiratory and Aerobic Responses Associated with Improved Endurance Exercise Performance Following Cold Drink Pre-Cooling in the Heat

This study investigated the physiological responses associated with improved endurance exercise performance following cold drink pre-cooling in the heat, with particular emphasis on respiratory and aerobic responses. Twenty trained male athletes completed three randomized trials: one trial under normothermic conditions with ingestion of a 7.5 mL/kg body weight (BW) ambient-temperature sports drink (Con), and two trials within a hot environment involving administration of either a 7.5 mL/kg BW normothermic sports drink (Non) or a 4 °C pre-cooled sports drink (Pre). Endurance exercise duration, cardiorespiratory function, heart rate (HR), core temperature (Tcore), and perceptual responses were measured during incremental cycling tests. Endurance exercise duration was significantly shorter in the Non condition than in the Con condition (p = 0.011), whereas no significant difference was observed between the Pre and Con conditions (p = 0.576). Within the hot environment, exercise duration was significantly longer in the Pre condition than in the Non condition (p = 0.009). At 10% of total exercise duration, BF (p = 0.028) and HR (p = 0.044) were significantly lower in the Pre condition than in the Non condition. At exhaustion, VEpeak (p = 0.013), BFpeak (p = 0.019), PetO2 (p = 0.005), and HRpeak (p = 0.014) were significantly higher in the Pre condition. Pre-cooling significantly reduced Tcore (p = 0.001) and thermal sensation (p < 0.001) at exercise onset, but these differences were no longer evident at exhaustion. In conclusion, pre-exercise ingestion of a 4 °C sport drink at 7.5 mL/kg BW mitigates heat-induced impairment in endurance exercise performance. These findings indicate that the ergogenic benefits of cold drink pre-cooling are primarily associated with reductions in initial thermal and cardiovascular strain, whereas the higher peak cardiorespiratory values observed at exhaustion likely represent terminal physiological responses rather than underlying mechanisms mediating the performance benefits.

Authors

Institutions

Publication Details

Journal
Life
Published
2026-11-17
DOI
https://doi.org/10.3390/life16111945
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Respiratory and Aerobic Responses Associated with Improved Endurance Exercise Performance Following Cold Drink Pre-Cooling in the Heat

Wantang Su, Laikang Yu, Yuanyuan Lv, Li Zhao et al.
Life
Thermoregulation and physiological responses
article

Respiratory and Aerobic Responses Associated with Improved Endurance Exercise Performance Following Cold Drink Pre-Cooling in the Heat

Wantang Su, Laikang Yu, Yuanyuan Lv, Li Zhao, Zhizhou Chen, Yunteng Wang
article en

Abstract

This study investigated the physiological responses associated with improved endurance exercise performance following cold drink pre-cooling in the heat, with particular emphasis on respiratory and aerobic responses. Twenty trained male athletes completed three randomized trials: one trial under normothermic conditions with ingestion of a 7.5 mL/kg body weight (BW) ambient-temperature sports drink (Con), and two trials within a hot environment involving administration of either a 7.5 mL/kg BW normothermic sports drink (Non) or a 4 °C pre-cooled sports drink (Pre). Endurance exercise duration, cardiorespiratory function, heart rate (HR), core temperature (Tcore), and perceptual responses were measured during incremental cycling tests. Endurance exercise duration was significantly shorter in the Non condition than in the Con condition (p = 0.011), whereas no significant difference was observed between the Pre and Con conditions (p = 0.576). Within the hot environment, exercise duration was significantly longer in the Pre condition than in the Non condition (p = 0.009). At 10% of total exercise duration, BF (p = 0.028) and HR (p = 0.044) were significantly lower in the Pre condition than in the Non condition. At exhaustion, VEpeak (p = 0.013), BFpeak (p = 0.019), PetO2 (p = 0.005), and HRpeak (p = 0.014) were significantly higher in the Pre condition. Pre-cooling significantly reduced Tcore (p = 0.001) and thermal sensation (p < 0.001) at exercise onset, but these differences were no longer evident at exhaustion. In conclusion, pre-exercise ingestion of a 4 °C sport drink at 7.5 mL/kg BW mitigates heat-induced impairment in endurance exercise performance. These findings indicate that the ergogenic benefits of cold drink pre-cooling are primarily associated with reductions in initial thermal and cardiovascular strain, whereas the higher peak cardiorespiratory values observed at exhaustion likely represent terminal physiological responses rather than underlying mechanisms mediating the performance benefits.

LifeVol. 16(11)
Beijing Sport University (CN)
Humanities and Social Science Fund of Ministry of Education of China
Good health and well-being
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon