Stereotactic centralized/core ablative radiation therapy: a dosimetric evaluation of dynamic conformal arc and volumetric modulated arc therapy

Objective To explore the differences in dose and plan parameters between Dynamic Conformal Arc (DCA) and Volumetric Modulated Arc Therapy (VMAT) in stereotactic centralized/core ablative radiation therapy (SCART), providing a reference for the technical choice of SCART on linear accelerators. Methods This is a single-center, retrospective analysis of 10 patients with bulky lung tumors. The prescription dose was 54Gy/3F using SCART. Treatment planning for DCA and VMAT was done with United Imaging Healthcare's uRT-TPOIS system. This study collected the dose results for the target volume and organs at risk (OARs), used the Wilcoxon signed-rank test for statistical analysis, and applied the Holm method for multiple comparisons to compare and observe the planning conditions of the two techniques. Results After applying Holm correction to the parameters of the target volume and OARs, only the maximum dose outside GTV and the V 5Gy of the lungs-GTV showed significant differences. The median Dmax outside GTV for DCA and VMAT were 7.45 and 6.18, respectively, with mean, standard deviation (SD), and standard error of the mean (SEM) being 1.30, 0.76, and 0.24. DCA-VMAT > 0 indicates a positive difference, otherwise negative; the 95% confidence interval ranged from 0.76 to 1.85, and the adjusted p-value was 0.028. For lungs-GTV, the medians were 12.53 and 11.36, with mean, SD, and SEM being 1.79, 1.22, and 0.39; the 95% confidence interval ranged from 0.91 to 2.66, and the adjusted p-value was 0.028. Conclusion In the plans applying DCA and VMAT to SCART, after multiple comparisons of dose parameters, it was found that overall, most parameter differences were not significant, with only the maximum dose outside GTV and the V 5Gy of lungs-GTV showing significant differences. This study compares the planning parameter statistics of DCA and VMAT techniques to evaluate the application of SCART on linear accelerators.

Authors

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2026-11-17
DOI
https://doi.org/10.1016/j.jrras.2026.102844
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Stereotactic centralized/core ablative radiation therapy: a dosimetric evaluation of dynamic conformal arc and volumetric modulated arc therapy

Yu Wang, Deying Xu, Yunfeng Liu, Liang Yu
Journal of Radiation Research and Applied Sciences
Advanced Radiotherapy Techniques
article

Stereotactic centralized/core ablative radiation therapy: a dosimetric evaluation of dynamic conformal arc and volumetric modulated arc therapy

Yu Wang, Deying Xu, Yunfeng Liu, Liang Yu
article en

Abstract

Objective To explore the differences in dose and plan parameters between Dynamic Conformal Arc (DCA) and Volumetric Modulated Arc Therapy (VMAT) in stereotactic centralized/core ablative radiation therapy (SCART), providing a reference for the technical choice of SCART on linear accelerators. Methods This is a single-center, retrospective analysis of 10 patients with bulky lung tumors. The prescription dose was 54Gy/3F using SCART. Treatment planning for DCA and VMAT was done with United Imaging Healthcare's uRT-TPOIS system. This study collected the dose results for the target volume and organs at risk (OARs), used the Wilcoxon signed-rank test for statistical analysis, and applied the Holm method for multiple comparisons to compare and observe the planning conditions of the two techniques. Results After applying Holm correction to the parameters of the target volume and OARs, only the maximum dose outside GTV and the V 5Gy of the lungs-GTV showed significant differences. The median Dmax outside GTV for DCA and VMAT were 7.45 and 6.18, respectively, with mean, standard deviation (SD), and standard error of the mean (SEM) being 1.30, 0.76, and 0.24. DCA-VMAT > 0 indicates a positive difference, otherwise negative; the 95% confidence interval ranged from 0.76 to 1.85, and the adjusted p-value was 0.028. For lungs-GTV, the medians were 12.53 and 11.36, with mean, SD, and SEM being 1.79, 1.22, and 0.39; the 95% confidence interval ranged from 0.91 to 2.66, and the adjusted p-value was 0.028. Conclusion In the plans applying DCA and VMAT to SCART, after multiple comparisons of dose parameters, it was found that overall, most parameter differences were not significant, with only the maximum dose outside GTV and the V 5Gy of lungs-GTV showing significant differences. This study compares the planning parameter statistics of DCA and VMAT techniques to evaluate the application of SCART on linear accelerators.

Journal of Radiation Research and Applied SciencesVol. 19(4)
Ministry of Science and Technology of the People's Republic of China
Good health and well-being
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon