Integrated Pulsed Field Ablation Improves Procedural Efficiency Compared With Radiofrequency for Pulmonary Vein Isolation: A Multicenter Real-World Analysis

Abstract Background : Integrated pulsed field ablation (PFA) platforms combine nonthermal lesion delivery with electroanatomic mapping and may improve procedural workflow during atrial fibrillation (AF). Real-world comparisons with contemporary radiofrequency (RF) ablation remain limited. Objectives : To compare procedural efficiency between integrated PFA and conventional RF ablation for pulmonary vein isolation (PVI), while maintaining acute procedural efficacy. Methods : In this prospective, multicenter, nonrandomized study across 6 tertiary centers, consecutive patients undergoing first-time PVI for paroxysmal or persistent AF were included. Procedures were performed using integrated PFA (Varipulse™) or RF (SmartTouch SF™ or QDOT Micro™) ablation at operator discretion. The primary endpoint was total procedure time. Secondary endpoints included ablation and mapping duration, first-pass isolation (FPI), fluoroscopy time, additional lesions requirements, anesthesia strategy, and learning curve analysis. Result : A total of 503 procedures (203 PFA, 300 RF) were analyzed. Acute PVI was achieved in 100% of cases. Procedure time was shorter with PFA than RF (93.3 vs 115.3 minutes; difference –22.1 minutes; p < 0.0001). PFA reduced ablation (–17.0 minutes; p < 0.0001) and mapping time (p = 0.0005) and achieved higher FPI rates (93.1% vs 85.8%; p < 0.0001). Additional lesions beyond PVI were less frequent with PFA (1.97% vs 19.33%, p < 0.0001). Fluoroscopy time was modestly higher in the PFA group (+2.6 minutes; p = 0.0004). Ablation duration decreased significantly within the first 15 cases. Conclusions : Integrated PFA significantly improved procedural efficiency compared with RF ablation while maintaining acute PVI success, supporting its potential to enhance electrophysiology laboratory workflow.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11244630/v1
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Integrated Pulsed Field Ablation Improves Procedural Efficiency Compared With Radiofrequency for Pulmonary Vein Isolation: A Multicenter Real-World Analysis

Amaya García Fernández, José Luis Martínez‐Sande, Nuria Rivas‐Gándara, Jesús Alberto Fernández López et al.
5 links
Research Square
Atrial Fibrillation Management and Outcomes
preprint

Integrated Pulsed Field Ablation Improves Procedural Efficiency Compared With Radiofrequency for Pulmonary Vein Isolation: A Multicenter Real-World Analysis

Amaya García Fernández, José Luis Martínez‐Sande, Nuria Rivas‐Gándara, Jesús Alberto Fernández López, Nuria Basterra Sola, Óscar Alcalde, Francisco Javier García-Seara, Thomas André Brouzet, Carlos Minguito Carazo, Jaume Francisco‐Pascual, Alicia Ibáñez-Críado, Javier Romero Roldán, Moisés Rodríguez‐Mañero, Javier Martínez Basterra, Jesmar Alejandro Ramonis Quintero, Javier Gómez Bodas, Francisco Ribes Tur, Carlos Gil Guillén, Pablo Torres Costales, Jordi Pérez Rodón, Raquel Adeliño Recasens, Federico Segura Villalobos, Pablo Ramos Ardanáz, Víctor Pérez Rosselló, Nerea Mosquera Garrote, Javier Alejandro Bellver Navarro, Alba Santos Ortega
preprint en

Abstract

Abstract Background : Integrated pulsed field ablation (PFA) platforms combine nonthermal lesion delivery with electroanatomic mapping and may improve procedural workflow during atrial fibrillation (AF). Real-world comparisons with contemporary radiofrequency (RF) ablation remain limited. Objectives : To compare procedural efficiency between integrated PFA and conventional RF ablation for pulmonary vein isolation (PVI), while maintaining acute procedural efficacy. Methods : In this prospective, multicenter, nonrandomized study across 6 tertiary centers, consecutive patients undergoing first-time PVI for paroxysmal or persistent AF were included. Procedures were performed using integrated PFA (Varipulse™) or RF (SmartTouch SF™ or QDOT Micro™) ablation at operator discretion. The primary endpoint was total procedure time. Secondary endpoints included ablation and mapping duration, first-pass isolation (FPI), fluoroscopy time, additional lesions requirements, anesthesia strategy, and learning curve analysis. Result : A total of 503 procedures (203 PFA, 300 RF) were analyzed. Acute PVI was achieved in 100% of cases. Procedure time was shorter with PFA than RF (93.3 vs 115.3 minutes; difference –22.1 minutes; p < 0.0001). PFA reduced ablation (–17.0 minutes; p < 0.0001) and mapping time (p = 0.0005) and achieved higher FPI rates (93.1% vs 85.8%; p < 0.0001). Additional lesions beyond PVI were less frequent with PFA (1.97% vs 19.33%, p < 0.0001). Fluoroscopy time was modestly higher in the PFA group (+2.6 minutes; p = 0.0004). Ablation duration decreased significantly within the first 15 cases. Conclusions : Integrated PFA significantly improved procedural efficiency compared with RF ablation while maintaining acute PVI success, supporting its potential to enhance electrophysiology laboratory workflow.

Research Square
Hebron University (PS), Universidade de Santiago de Compostela (ES), Complejo Hospitalario Universitario de Santiago (ES), Vall d'Hebron Institut de Recerca (ES), Hospital General Universitari de Castelló (ES), Vall d'Hebron Hospital Universitari (ES), Hospital General Universitario de Alicante Doctor Balmis (ES)
Good health and well-being
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon