The energy of the atoms from the clouds of the directional-product model: helium to krypton without screening constants (version 2)

Version 2: corrected and rewritten; it replaces version 1 (doi:10.5281/zenodo.24304038). Main changes in this version:1. Numerical correction. Version 1 began the integration grid at r = 1.7×10⁻⁵ bohr, so a small part of the kinetic energy of s clouds near the nucleus was lost (1.6×10⁻⁴ hartree in helium, up to 0.13% of the total in krypton). The grid now begins at 5×10⁻¹² bohr. All numbers are recomputed. No registered verdict changes. Corrected statements: Li–Ar within 1.04% (Ne −1.04%); K–Kr all within 0.58% and closer to measurement than Slater's constants in 17 of 18 atoms (version 1: 0.46% and 18 of 18); relativistic part in Kr 986 eV (version 1: 997 eV); screening of 1s by its partner 0.29–0.32.2. Direction of the route. At every step the part that comes from the model is stated first, followed by its "meaning" and a "check" against the known result.3. Known tools named. The energy expression of the clouds is the known Slater–Condon energy of the average of configuration, with 3j coefficients, and it is now stated as a tool. The model supplies the clouds, their nodes (from the independence of the strings of the modulo-30 wheel), the placement of the electrons on the mirror pairs of the wheel, and the relativistic part from the fractional function. New checks are stated: the clouds are the Schrödinger states of hydrogen, two senses on one mirror pair is the Pauli rule, and the pair coordinates are those of Hylleraas.4. Additions: a table of symbols; three comparison charts with the corrected numbers (deviation from NIST, He to Kr, model against Slater's constants; K–Kr bars; effective charges found by the model against Slater's rules); a table of what the model led to; and a pointer to the later paper (doi:10.5281/zenodo.24332811), in which clouds with two widths and electron pairs bring all atoms from sodium to argon closer to measurement than Slater's constants (within 0.12%). Results (corrected grid):- The energy is computed from the clouds of the model, with no screening constant and no measured value.- He–Ar: Li–Ar within 1.04% and Si–Ar within 0.59%; registered verdict "near" (He 1.9%). In these light atoms Slater's constants remain closer.- K–Kr: all 18 within 0.58% (registered verdict: success). The model is closer than Slater's constants in 17 of 18, and the gap grows with Z (Kr: −0.42% against −1.79%).- Helium with the pair of electrons read by the directional product (half-sum, half-difference, distance): −0.028%. First٠ ionisation energy −0.12%.- Slater's screening constants emerge as results: screening of 1s by its partner 0.29–0.32 (Slater 0.30); 2p charges within 2.3%. Artificial intelligence was used to verify the accuracy of the information.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-17
DOI
https://doi.org/10.5281/zenodo.24304037
Primary Topic
Atomic and Molecular Physics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

The energy of the atoms from the clouds of the directional-product model: helium to krypton without screening constants (version 2)

Modhar Mohammed Torki Msliki, Fawaz Modhar Maliki
1 links
Zenodo (CERN European Organization for Nuclear Research)
Atomic and Molecular Physics
preprint

The energy of the atoms from the clouds of the directional-product model: helium to krypton without screening constants (version 2)

Modhar Mohammed Torki Msliki, Fawaz Modhar Maliki
preprint en

Abstract

Version 2: corrected and rewritten; it replaces version 1 (doi:10.5281/zenodo.24304038). Main changes in this version:1. Numerical correction. Version 1 began the integration grid at r = 1.7×10⁻⁵ bohr, so a small part of the kinetic energy of s clouds near the nucleus was lost (1.6×10⁻⁴ hartree in helium, up to 0.13% of the total in krypton). The grid now begins at 5×10⁻¹² bohr. All numbers are recomputed. No registered verdict changes. Corrected statements: Li–Ar within 1.04% (Ne −1.04%); K–Kr all within 0.58% and closer to measurement than Slater's constants in 17 of 18 atoms (version 1: 0.46% and 18 of 18); relativistic part in Kr 986 eV (version 1: 997 eV); screening of 1s by its partner 0.29–0.32.2. Direction of the route. At every step the part that comes from the model is stated first, followed by its "meaning" and a "check" against the known result.3. Known tools named. The energy expression of the clouds is the known Slater–Condon energy of the average of configuration, with 3j coefficients, and it is now stated as a tool. The model supplies the clouds, their nodes (from the independence of the strings of the modulo-30 wheel), the placement of the electrons on the mirror pairs of the wheel, and the relativistic part from the fractional function. New checks are stated: the clouds are the Schrödinger states of hydrogen, two senses on one mirror pair is the Pauli rule, and the pair coordinates are those of Hylleraas.4. Additions: a table of symbols; three comparison charts with the corrected numbers (deviation from NIST, He to Kr, model against Slater's constants; K–Kr bars; effective charges found by the model against Slater's rules); a table of what the model led to; and a pointer to the later paper (doi:10.5281/zenodo.24332811), in which clouds with two widths and electron pairs bring all atoms from sodium to argon closer to measurement than Slater's constants (within 0.12%). Results (corrected grid):- The energy is computed from the clouds of the model, with no screening constant and no measured value.- He–Ar: Li–Ar within 1.04% and Si–Ar within 0.59%; registered verdict "near" (He 1.9%). In these light atoms Slater's constants remain closer.- K–Kr: all 18 within 0.58% (registered verdict: success). The model is closer than Slater's constants in 17 of 18, and the gap grows with Z (Kr: −0.42% against −1.79%).- Helium with the pair of electrons read by the directional product (half-sum, half-difference, distance): −0.028%. First٠ ionisation energy −0.12%.- Slater's screening constants emerge as results: screening of 1s by its partner 0.29–0.32 (Slater 0.30); 2p charges within 2.3%. Artificial intelligence was used to verify the accuracy of the information.

Zenodo (CERN European Organization for Nuclear Research)
University of Basrah (IQ)
Atomic and Molecular Physics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon