Measurement uncertainty for the quantification of serum CysC by ID-LC-MS/MS method

Abstract Objective Taking Cystatin-C (CysC) measurement uncertainty (MU) evaluation as an example to help researches to better understand the accuracy and limitations of results obtained by ID-LC-MS/MS method. Methods According to GUM principle, we summarized the MU evaluation process in the following four steps:1) Specification of the measurand, which is the mass concentration of CysC in serum. Then set a model equation between the measurand and everything important that affects it; 2)Identification of the uncertainty sources, we took pre-analytical (high-abundance protein depletion, trypsin digestion and solid-phase extraction) and analytical (calibration curve establishment and measurement imprecision) phases uncertainty sources into account; 3) Quantification and standardization of the uncertainty components, the detailed evaluation of the uncertainty components is either based on statistical methods (type A) or other methods (type B) and requires that the analyst makes assumptions regarding the underlying distribution (rectangular, triangular, normal, etc.); 4) Calculation of the combined standard uncertainty ( u c ) and expanded uncertainty ( U, k = 2) . Results The relative uncertainty of u RE protein %, u calibration−curve %, u RE hydrolysis %, u RE SPE %, u imp % are 0.64%, 4.16%, 2.04%, 0.30% and 0.73% for y 9 , and 0.64%, 1.23%, 2.24%, 0.27% and 0.77% for y 6 . The u c are 4.77% and 2.79% for y 9 and y 6 , respectively. And the U are 9.54% and 5.58% ( k = 2) for y 9 and y 6 , respectively. Conclusion The two major contributions to total uncertainty arise from trypsin digestion and calibration curve, which account for 78.9% and 67.9% for y 9 and y 6 , respectively. So we should strictly control the two processes when quantification of serum CysC by ID-LC-MS/MS.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11497448/v1
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Measurement uncertainty for the quantification of serum CysC by ID-LC-MS/MS method

季伙燕, Yiwen HUANG, Ziyi Zhang, Chen Qian et al.
1 links
Research Square
Scientific Measurement and Uncertainty Evaluation
preprint

Measurement uncertainty for the quantification of serum CysC by ID-LC-MS/MS method

季伙燕, Yiwen HUANG, Ziyi Zhang, Chen Qian, Xinlei Wang
preprint en

Abstract

Abstract Objective Taking Cystatin-C (CysC) measurement uncertainty (MU) evaluation as an example to help researches to better understand the accuracy and limitations of results obtained by ID-LC-MS/MS method. Methods According to GUM principle, we summarized the MU evaluation process in the following four steps:1) Specification of the measurand, which is the mass concentration of CysC in serum. Then set a model equation between the measurand and everything important that affects it; 2)Identification of the uncertainty sources, we took pre-analytical (high-abundance protein depletion, trypsin digestion and solid-phase extraction) and analytical (calibration curve establishment and measurement imprecision) phases uncertainty sources into account; 3) Quantification and standardization of the uncertainty components, the detailed evaluation of the uncertainty components is either based on statistical methods (type A) or other methods (type B) and requires that the analyst makes assumptions regarding the underlying distribution (rectangular, triangular, normal, etc.); 4) Calculation of the combined standard uncertainty ( u c ) and expanded uncertainty ( U, k = 2) . Results The relative uncertainty of u RE protein %, u calibration−curve %, u RE hydrolysis %, u RE SPE %, u imp % are 0.64%, 4.16%, 2.04%, 0.30% and 0.73% for y 9 , and 0.64%, 1.23%, 2.24%, 0.27% and 0.77% for y 6 . The u c are 4.77% and 2.79% for y 9 and y 6 , respectively. And the U are 9.54% and 5.58% ( k = 2) for y 9 and y 6 , respectively. Conclusion The two major contributions to total uncertainty arise from trypsin digestion and calibration curve, which account for 78.9% and 67.9% for y 9 and y 6 , respectively. So we should strictly control the two processes when quantification of serum CysC by ID-LC-MS/MS.

Research Square
Affiliated Hospital of Nantong University (CN)
National Key Research and Development Program of China
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon