Tribological and microstructural characterization of UHMWPE fibre- graphene epoxy hybrid composite under dry sliding

Epoxy resins are brittle and wear rapidly when sliding against steel. This study examines the dry sliding wear and friction of hybrid composites in which short, untreated ultra-high-molecular-weight polyethylene (UHMWPE) fibre (12 mm long, 1–5 phr) was added to an LY556/HY951 epoxy matrix containing 1 phr graphene nanoplatelets (GNP). The five hybrids (EGU1–EGU5) were prepared by liquid-phase processing (sequential mechanical stirring and bath sonication, casting and vacuum degassing) and tested on a pin-on-disc tribometer against EN31 steel. Sliding time (5, 10 and 15 min), normal load (10, 20 and 30 N) and disc speed (500, 600 and 700 rpm) were arranged in a Taguchi L9 orthogonal array, and the 45 tests were analysed by main-effects analysis of variance (ANOVA). Over the nine conditions, the mean wear depth decreased from 626.7 ± 491.0 µm for EGU1 to 260.6 ± 128.9 µm for EGU5 (−58.4%), and the mean coefficient of friction from 0.501 ± 0.158 to 0.250 ± 0.096 (−50.1%), and the mean specific wear rate from 5.44 × 10−4 to 2.86 × 10−4 mm3 N−1 m−1 (−47%). Normal load (24.2% contribution, p = 0.0002), fibre content (17.0%, p = 0.012) and sliding time (16.1%, p = 0.0025) had significant effects on wear, whereas sliding speed did not (p = 0.15), and fibre content was the only significant factor for friction (31.4%, p = 0.0086). The fibres were most effective at high load, with EGU5 wearing 74.7% less than EGU1 at 30 N, compared with 42.0% less at 10 N. Vickers microhardness rose from 23.2 to 35.3 HV between EGU1 and EGU5. Scanning electron microscopy of the worn pins showed that the wear mechanism changed from fatigue-assisted delamination in EGU1 to mild abrasion with a thin smeared layer in EGU5. Within the conditions tested, 4–5 phr UHMWPE fibre gave the lowest wear and friction.

Authors

Publication Details

Journal
Figshare
Published
2026-11-17
DOI
https://doi.org/10.6084/m9.figshare.35039876
Primary Topic
Tribology and Wear Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Tribological and microstructural characterization of UHMWPE fibre- graphene epoxy hybrid composite under dry sliding

Rajendra Prasad, Veena Pani R, Manjunatha L. H., Jaya Kishore S.
Figshare
Tribology and Wear Analysis
article

Tribological and microstructural characterization of UHMWPE fibre- graphene epoxy hybrid composite under dry sliding

Rajendra Prasad, Veena Pani R, Manjunatha L. H., Jaya Kishore S.
article en

Abstract

Epoxy resins are brittle and wear rapidly when sliding against steel. This study examines the dry sliding wear and friction of hybrid composites in which short, untreated ultra-high-molecular-weight polyethylene (UHMWPE) fibre (12 mm long, 1–5 phr) was added to an LY556/HY951 epoxy matrix containing 1 phr graphene nanoplatelets (GNP). The five hybrids (EGU1–EGU5) were prepared by liquid-phase processing (sequential mechanical stirring and bath sonication, casting and vacuum degassing) and tested on a pin-on-disc tribometer against EN31 steel. Sliding time (5, 10 and 15 min), normal load (10, 20 and 30 N) and disc speed (500, 600 and 700 rpm) were arranged in a Taguchi L9 orthogonal array, and the 45 tests were analysed by main-effects analysis of variance (ANOVA). Over the nine conditions, the mean wear depth decreased from 626.7 ± 491.0 µm for EGU1 to 260.6 ± 128.9 µm for EGU5 (−58.4%), and the mean coefficient of friction from 0.501 ± 0.158 to 0.250 ± 0.096 (−50.1%), and the mean specific wear rate from 5.44 × 10−4 to 2.86 × 10−4 mm3 N−1 m−1 (−47%). Normal load (24.2% contribution, p = 0.0002), fibre content (17.0%, p = 0.012) and sliding time (16.1%, p = 0.0025) had significant effects on wear, whereas sliding speed did not (p = 0.15), and fibre content was the only significant factor for friction (31.4%, p = 0.0086). The fibres were most effective at high load, with EGU5 wearing 74.7% less than EGU1 at 30 N, compared with 42.0% less at 10 N. Vickers microhardness rose from 23.2 to 35.3 HV between EGU1 and EGU5. Scanning electron microscopy of the worn pins showed that the wear mechanism changed from fatigue-assisted delamination in EGU1 to mild abrasion with a thin smeared layer in EGU5. Within the conditions tested, 4–5 phr UHMWPE fibre gave the lowest wear and friction.

Figshare
Tribology and Wear Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon