Ergonomic Setup for Trans‐Radial Procedures Using a Height‐Adjustable Trolley in the Angiography Suite

BACKGROUND: Trans-radial access (TRA), while experiencing varying global adoption among interventional radiologists, offers potential benefits including reduced access-site bleeding, accelerated patient ambulation, and decreased overall healthcare expenditures compared with trans-femoral access (TFA). However, TRA introduces distinct occupational ergonomic burdens, including asymmetrical arm abduction, working height discrepancies with standard angiographic tables, and inadequate support for long microcatheters and guidewires. These biomechanical constraints heighten operator fatigue and increase the cumulative risk of work-related musculoskeletal disorders. TECHNIQUE: A mobile, height-adjustable trolley-conceptually adapted from ergonomic sit-stand workstations-was integrated into the angiography suite workflow. Arranged parallel to the patient in a Z-shaped spatial configuration, the trolley is linked to the patient's outstretched access arm using an extended sterile drape to establish a stable, continuous sterile working platform. CLINICAL IMPLICATIONS: This technical configuration restores neutral operator posture, mitigates lumbar torsion and cervical strain, eliminates sterile field breaches from suspended equipment, and increases the physical working distance from primary scatter radiation sources. Furthermore, the elevated surface facilitates gravity-assisted administration of dense Yttrium-90 microspheres during radioembolization and prevents rotational interference during cone-beam computed tomography acquisitions. CONCLUSION: The implementation of a height-adjustable trolley provides a simple, cost-effective, and highly adaptable ergonomic solution that optimizes procedural efficiency, sterile field integrity, and radiation safety during trans-radial interventional procedures.

Authors

Institutions

Publication Details

Journal
Journal of Medical Imaging and Radiation Oncology
Published
2026-11-16
DOI
https://doi.org/10.1111/1754-9485.70223
Primary Topic
Vascular Procedures and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Ergonomic Setup for Trans‐Radial Procedures Using a Height‐Adjustable Trolley in the Angiography Suite

Akshay Kohli, Glen Schlaphoff, Terrence Chi Hong Hui
Journal of Medical Imaging and Radiation Oncology
Vascular Procedures and Complications
article

Ergonomic Setup for Trans‐Radial Procedures Using a Height‐Adjustable Trolley in the Angiography Suite

Akshay Kohli, Glen Schlaphoff, Terrence Chi Hong Hui
article en

Abstract

BACKGROUND: Trans-radial access (TRA), while experiencing varying global adoption among interventional radiologists, offers potential benefits including reduced access-site bleeding, accelerated patient ambulation, and decreased overall healthcare expenditures compared with trans-femoral access (TFA). However, TRA introduces distinct occupational ergonomic burdens, including asymmetrical arm abduction, working height discrepancies with standard angiographic tables, and inadequate support for long microcatheters and guidewires. These biomechanical constraints heighten operator fatigue and increase the cumulative risk of work-related musculoskeletal disorders. TECHNIQUE: A mobile, height-adjustable trolley-conceptually adapted from ergonomic sit-stand workstations-was integrated into the angiography suite workflow. Arranged parallel to the patient in a Z-shaped spatial configuration, the trolley is linked to the patient's outstretched access arm using an extended sterile drape to establish a stable, continuous sterile working platform. CLINICAL IMPLICATIONS: This technical configuration restores neutral operator posture, mitigates lumbar torsion and cervical strain, eliminates sterile field breaches from suspended equipment, and increases the physical working distance from primary scatter radiation sources. Furthermore, the elevated surface facilitates gravity-assisted administration of dense Yttrium-90 microspheres during radioembolization and prevents rotational interference during cone-beam computed tomography acquisitions. CONCLUSION: The implementation of a height-adjustable trolley provides a simple, cost-effective, and highly adaptable ergonomic solution that optimizes procedural efficiency, sterile field integrity, and radiation safety during trans-radial interventional procedures.

Journal of Medical Imaging and Radiation Oncology
Liverpool Hospital (AU), Tan Tock Seng Hospital (SG)
Vascular Procedures and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon