Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes

This study investigates the dynamic efficacy of Fluid Viscous Dampers (FVDs) in mitigating lateral story drift and attenuating seismic base shear forces in multi-story steel moment-resisting frames (MRFs) subjected to contrasting geotechnical site conditions. Archetype steel structures with 5, 10, and 15 stories were designed in full compliance with the Turkish Building Earthquake Code (TBDY-2018) and AISC 360-16 specifications, considering hard rock (ZA) and soft, deep sedimentary soil deposits (ZE) for high-seismicity coordinates along the East Anatolian Fault zone (Pazarcık, Kahramanmaraş). A suite of 11 real earthquake acceleration pairs (22 horizontal components) compiled from the AFAD TADAS database was spectrally matched to code-compliant target elastic response spectra using continuous wavelet transforms. Direct integration nonlinear time-history analyses (NL-THA) were executed using the Newmark average acceleration method. Modal eigenvalue analyses confirm that supplemental diagonal FVDs preserve the fundamental natural vibration periods of the frames (T1 = 0.70 s, 1.53 s, and 1.53 s for the 5-, 10-, and 15-story archetypes, respectively) without imposing secondary elastic stiffness penalties. The nonlinear dynamic findings demonstrate that FVD integration reduces peak lateral floor displacements by 54.59% to 88.05% and suppresses maximum base shear demands by 69.10% to 85.29% across all heights and shaking directions. Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelihood of plastic hinge formation and precluding second-order P − Δ collapse mechanisms.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-17
DOI
https://doi.org/10.3390/buildings16224580
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes

Ertuğrul Çambay, Cenk ÇONTAY
1 links
Buildings
Seismic Performance and Analysis
article

Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes

Ertuğrul Çambay, Cenk ÇONTAY
article en

Abstract

This study investigates the dynamic efficacy of Fluid Viscous Dampers (FVDs) in mitigating lateral story drift and attenuating seismic base shear forces in multi-story steel moment-resisting frames (MRFs) subjected to contrasting geotechnical site conditions. Archetype steel structures with 5, 10, and 15 stories were designed in full compliance with the Turkish Building Earthquake Code (TBDY-2018) and AISC 360-16 specifications, considering hard rock (ZA) and soft, deep sedimentary soil deposits (ZE) for high-seismicity coordinates along the East Anatolian Fault zone (Pazarcık, Kahramanmaraş). A suite of 11 real earthquake acceleration pairs (22 horizontal components) compiled from the AFAD TADAS database was spectrally matched to code-compliant target elastic response spectra using continuous wavelet transforms. Direct integration nonlinear time-history analyses (NL-THA) were executed using the Newmark average acceleration method. Modal eigenvalue analyses confirm that supplemental diagonal FVDs preserve the fundamental natural vibration periods of the frames (T1 = 0.70 s, 1.53 s, and 1.53 s for the 5-, 10-, and 15-story archetypes, respectively) without imposing secondary elastic stiffness penalties. The nonlinear dynamic findings demonstrate that FVD integration reduces peak lateral floor displacements by 54.59% to 88.05% and suppresses maximum base shear demands by 69.10% to 85.29% across all heights and shaking directions. Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelihood of plastic hinge formation and precluding second-order P − Δ collapse mechanisms.

BuildingsVol. 16(22)
Bitlis Eren University (TR)
Sustainable cities and communities
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon