CAPE-DT: A Context-Aware Place-Based Energy Digital Twin for Sustainable and Equitable Cellular Networks

Digital infrastructure increasingly supports transportation, public safety, healthcare, emergency response, and other essential urban services, but the mobile networks enabling these functions also consume substantial energy. Reducing radio access network energy use can advance urban sustainability, yet conventional energy-saving strategies are typically evaluated through network-wide efficiency and quality-of-service metrics that do not reveal where service degradation occurs or who is most exposed. This study develops CAPE-DT, a Context-Aware Place-Based Energy Digital Twin, to evaluate this trade-off across space and changing operating conditions. CAPE-DT organizes four layers on a common lattice: a context layer representing seasonal demand, transportation activity, localized demand surges, and county electric-power outages; an infrastructure layer representing modeled cell-site locations, reported per-operator service availability, and communication redundancy; a place layer representing population, social vulnerability, critical facilities, and flood exposure; and a network layer in which control decisions are evaluated. A what-if scenario generator examines normal, seasonal-peak, localized-surge, and infrastructure-disruption conditions. Applied to Cape May County, New Jersey, CAPE-Control reduces modeled annual network energy use by 435 MWh (25.9%) and associated operational CO2-equivalent emissions by 118 t while satisfying a by-design constraint of no additional loss in any-operator availability in the no-failure case. Energy-First saves 1086 MWh (64.6%) but adds 6.17 percentage points of lost person-minutes on a winter weekday. The results indicate that, in this county, reported communication redundancy bounds how much energy can be saved without shifting connectivity risk toward places with fewer service alternatives. CAPE-DT links urban analytics, decarbonization, resilience, and distributional equity through place-based sustainability indicators mapped to SDG targets 11.5 and 11.b.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-11-17
DOI
https://doi.org/10.3390/su182211687
Primary Topic
Green IT and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

CAPE-DT: A Context-Aware Place-Based Energy Digital Twin for Sustainable and Equitable Cellular Networks

Dario Pompili, Safiyeh Tayebi, Adhwaa Alchaab
Sustainability
Green IT and Sustainability
article

CAPE-DT: A Context-Aware Place-Based Energy Digital Twin for Sustainable and Equitable Cellular Networks

Dario Pompili, Safiyeh Tayebi, Adhwaa Alchaab
article en

Abstract

Digital infrastructure increasingly supports transportation, public safety, healthcare, emergency response, and other essential urban services, but the mobile networks enabling these functions also consume substantial energy. Reducing radio access network energy use can advance urban sustainability, yet conventional energy-saving strategies are typically evaluated through network-wide efficiency and quality-of-service metrics that do not reveal where service degradation occurs or who is most exposed. This study develops CAPE-DT, a Context-Aware Place-Based Energy Digital Twin, to evaluate this trade-off across space and changing operating conditions. CAPE-DT organizes four layers on a common lattice: a context layer representing seasonal demand, transportation activity, localized demand surges, and county electric-power outages; an infrastructure layer representing modeled cell-site locations, reported per-operator service availability, and communication redundancy; a place layer representing population, social vulnerability, critical facilities, and flood exposure; and a network layer in which control decisions are evaluated. A what-if scenario generator examines normal, seasonal-peak, localized-surge, and infrastructure-disruption conditions. Applied to Cape May County, New Jersey, CAPE-Control reduces modeled annual network energy use by 435 MWh (25.9%) and associated operational CO2-equivalent emissions by 118 t while satisfying a by-design constraint of no additional loss in any-operator availability in the no-failure case. Energy-First saves 1086 MWh (64.6%) but adds 6.17 percentage points of lost person-minutes on a winter weekday. The results indicate that, in this county, reported communication redundancy bounds how much energy can be saved without shifting connectivity risk toward places with fewer service alternatives. CAPE-DT links urban analytics, decarbonization, resilience, and distributional equity through place-based sustainability indicators mapped to SDG targets 11.5 and 11.b.

SustainabilityVol. 18(22)
Rutgers, The State University of New Jersey (US)
Industry, innovation and infrastructure, Climate action, Sustainable cities and communities, Affordable and clean energy
Green IT and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.