Advancing Musculoskeletal Imaging With Motorized Three-Dimensional Ultrasound: System Development and Proof-of-Concept Application in Flexor Tendon Repair

Purpose Two-dimensional ultrasound is among the most widely used modalities in musculoskeletal imaging, but it collapses three-dimensional anatomy into a single plane and is operator-dependent, limiting volumetric and contextual assessment. Our purpose was to develop a motorized three-dimensional ultrasound platform that produces reproducible volumetric reconstructions from sequential two-dimensional images using standard clinical hardware and to demonstrate its performance in a clinical setting. Methods A custom motorized jig translates a commercial linear array transducer along a fixed axis at a controlled rate while transverse images are captured at 30 frames per second, giving a frame spacing of approximately 0.06 mm. Frames are aligned and stacked into a volumetric model that can be sectioned in any plane and segmented for volumetric measurement. To demonstrate the platform clinically, we applied it to one illustrative application—quantification of peritendinous scar tissue volume (STV) after flexor tendon repair—in patients enrolled at one academic medical center between November 2019 and May 2020, with range of motion (ROM) recorded during routine hand therapy. Results Volumetric reconstruction was achieved at every imaging session. Although acquisition was exclusively transverse, the reconstructed models permitted multiplanar reformatting and visualization of the flexor tendon along its entire longitudinal axis, and supported segmentation and volumetric measurement of individual structures. Nine patients were enrolled; three (all male; mean age 44 years, range 23–61; all zone II) completed serial imaging and ROM measurement. STV was measurable at every time point, and reductions in STV broadly accompanied gains in ROM. Conclusions Motorized three-dimensional ultrasound produces volumetric musculoskeletal reconstructions using equipment already available in the office. Scar quantification after tendon repair is one illustrative application; the platform is adaptable to any structure for which volumetric or contextual information matters, including nerves, vessels, and soft tissue masses. Type of study/level of evidence Diagnostic IV.

Authors

Institutions

Publication Details

Journal
Journal of Hand Surgery Global Online
Published
2026-11-17
DOI
https://doi.org/10.1016/j.jhsg.2026.101195
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Advancing Musculoskeletal Imaging With Motorized Three-Dimensional Ultrasound: System Development and Proof-of-Concept Application in Flexor Tendon Repair

Marlin Myers, Constantinos Ketonis, Alayna E. Loiselle, Wei Li et al.
Journal of Hand Surgery Global Online
Ultrasound in Clinical Applications
article

Advancing Musculoskeletal Imaging With Motorized Three-Dimensional Ultrasound: System Development and Proof-of-Concept Application in Flexor Tendon Repair

Marlin Myers, Constantinos Ketonis, Alayna E. Loiselle, Wei Li, Laura Glaser
article en

Abstract

Purpose Two-dimensional ultrasound is among the most widely used modalities in musculoskeletal imaging, but it collapses three-dimensional anatomy into a single plane and is operator-dependent, limiting volumetric and contextual assessment. Our purpose was to develop a motorized three-dimensional ultrasound platform that produces reproducible volumetric reconstructions from sequential two-dimensional images using standard clinical hardware and to demonstrate its performance in a clinical setting. Methods A custom motorized jig translates a commercial linear array transducer along a fixed axis at a controlled rate while transverse images are captured at 30 frames per second, giving a frame spacing of approximately 0.06 mm. Frames are aligned and stacked into a volumetric model that can be sectioned in any plane and segmented for volumetric measurement. To demonstrate the platform clinically, we applied it to one illustrative application—quantification of peritendinous scar tissue volume (STV) after flexor tendon repair—in patients enrolled at one academic medical center between November 2019 and May 2020, with range of motion (ROM) recorded during routine hand therapy. Results Volumetric reconstruction was achieved at every imaging session. Although acquisition was exclusively transverse, the reconstructed models permitted multiplanar reformatting and visualization of the flexor tendon along its entire longitudinal axis, and supported segmentation and volumetric measurement of individual structures. Nine patients were enrolled; three (all male; mean age 44 years, range 23–61; all zone II) completed serial imaging and ROM measurement. STV was measurable at every time point, and reductions in STV broadly accompanied gains in ROM. Conclusions Motorized three-dimensional ultrasound produces volumetric musculoskeletal reconstructions using equipment already available in the office. Scar quantification after tendon repair is one illustrative application; the platform is adaptable to any structure for which volumetric or contextual information matters, including nerves, vessels, and soft tissue masses. Type of study/level of evidence Diagnostic IV.

Journal of Hand Surgery Global OnlineVol. 9(1)
University of Rochester Medical Center (US), University of Rochester (US)
University of Rochester, Medical Center, University of Rochester
Good health and well-being
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon