Endovascular management of an iatrogenic right hepatic artery injury with a covered stent following endoscopic extraction of a common bile duct stent: a case report

Abstract Background. Arterial haemorrhage related to indwelling biliary stents is a rare but life-threatening event. Most reported cases are delayed hepatic artery pseudoaneurysms that present with haemobilia and are managed by transarterial embolisation. We report an unusual mechanism: a 10 Fr plastic common bile duct (CBD) stent whose distal retention flap had eroded into the right hepatic artery. This was associated with chronic anaemia and then with acute arterial rupture when traction during routine stent removal dislodged the embedded flap from the arterial wall. The injury was treated with a flow-preserving covered stent in a transplant candidate. Case presentation. A 45-year-old White European man with histologically confirmed Crohn's disease and secondary primary sclerosing cholangitis with biliary cirrhosis (Child-Pugh B, MELD 23), listed for liver transplantation and undergoing regular endoscopic CBD stent exchanges, was investigated for chronic anaemia. During a routine endoscopic stent exchange, a blood clot was noted at the tip of the indwelling 10 Fr plastic CBD stent. Immediately after stent removal, brisk bleeding occurred from the major papilla and the patient became haemodynamically unstable. Review of a computed tomography (CT) scan obtained two days earlier showed the distal retention flap of the stent protruding into the right hepatic artery. Angiography confirmed focal contrast extravasation from the right hepatic artery, which was sealed with a 5 × 22 mm balloon-expandable covered stent. The artery and distal hepatic perfusion were preserved and bleeding stopped immediately. The patient had no recurrent bleeding and underwent successful liver transplantation seven months later. Conclusions. A blood clot on the tip of a biliary stent should be regarded as a warning sign of underlying arterial injury, and review of prior cross-sectional imaging can rapidly localise the source. In patients dependent on hepatic arterial flow, such as liver-transplant candidates, a covered stent offers a flow-preserving alternative to embolisation for a focal, accessible injury, although the resulting need for antiplatelet therapy must be weighed against the bleeding and peri-transplant risks.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-10190560/v1
Primary Topic
Gallbladder and Bile Duct Disorders
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Endovascular management of an iatrogenic right hepatic artery injury with a covered stent following endoscopic extraction of a common bile duct stent: a case report

Claudia Keerl, Franz Eigenmann, Michael Kostrzewa
1 links
Research Square
Gallbladder and Bile Duct Disorders
preprint

Endovascular management of an iatrogenic right hepatic artery injury with a covered stent following endoscopic extraction of a common bile duct stent: a case report

Claudia Keerl, Franz Eigenmann, Michael Kostrzewa
preprint en

Abstract

Abstract Background. Arterial haemorrhage related to indwelling biliary stents is a rare but life-threatening event. Most reported cases are delayed hepatic artery pseudoaneurysms that present with haemobilia and are managed by transarterial embolisation. We report an unusual mechanism: a 10 Fr plastic common bile duct (CBD) stent whose distal retention flap had eroded into the right hepatic artery. This was associated with chronic anaemia and then with acute arterial rupture when traction during routine stent removal dislodged the embedded flap from the arterial wall. The injury was treated with a flow-preserving covered stent in a transplant candidate. Case presentation. A 45-year-old White European man with histologically confirmed Crohn's disease and secondary primary sclerosing cholangitis with biliary cirrhosis (Child-Pugh B, MELD 23), listed for liver transplantation and undergoing regular endoscopic CBD stent exchanges, was investigated for chronic anaemia. During a routine endoscopic stent exchange, a blood clot was noted at the tip of the indwelling 10 Fr plastic CBD stent. Immediately after stent removal, brisk bleeding occurred from the major papilla and the patient became haemodynamically unstable. Review of a computed tomography (CT) scan obtained two days earlier showed the distal retention flap of the stent protruding into the right hepatic artery. Angiography confirmed focal contrast extravasation from the right hepatic artery, which was sealed with a 5 × 22 mm balloon-expandable covered stent. The artery and distal hepatic perfusion were preserved and bleeding stopped immediately. The patient had no recurrent bleeding and underwent successful liver transplantation seven months later. Conclusions. A blood clot on the tip of a biliary stent should be regarded as a warning sign of underlying arterial injury, and review of prior cross-sectional imaging can rapidly localise the source. In patients dependent on hepatic arterial flow, such as liver-transplant candidates, a covered stent offers a flow-preserving alternative to embolisation for a focal, accessible injury, although the resulting need for antiplatelet therapy must be weighed against the bleeding and peri-transplant risks.

Research Square
Kantonsspital Baden (CH)
Good health and well-being
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon