Reconstructing the range-normalized terminal QRS from V1 and V6 using the time-embedded 3D ECG

Objective. Can a fixed V1/V6 projection of the time-embedded 3D ECG estimate the final 40 ms of V2-V5 more accurately than a fitted single lead? Methods. We used simultaneous recordings from the Lobachevsky University Electrocardiography Database (LUDB), with cardiologist-annotated QRS complexes in all six chest leads. We fitted both models in 118 patients and tested them in 80 others. Root mean squared error (RMSE) is expressed in percentage points (pp) of the target lead's 10-second amplitude range. Results. In 733 test beats, patient-weighted terminal RMSE fell from 12.58 to 10.64 pp (difference 1.94 pp, 95% bootstrap confidence interval 1.30 to 2.55). Reductions were 3.23, 2.85 and 1.35 pp in V3, V4 and V5. In V2 the difference was 0.35 pp (95% interval -0.35 to 1.05). In 702 matched beats from 77 patients, the overall advantage was 2.22 pp at the automatic V1/V6 end and 1.92 pp at the annotated target end. Of 1,498 beat-lead pairs with whole-QRS correlation of at least 0.95, 28.84% still had terminal RMSE of at least 10 pp. Conclusions. A fixed V1/V6 projection improved offline estimates of relative terminal amplitude in V3-V5 without fitting the target lead in the new patient. The gain was largest in V3 and V4 and uncertain in V2. Whether a reconstructed trace preserves a clinically recognizable notch or slur remains untested.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-16
DOI
https://doi.org/10.64898/2026.11.14.26368083
Primary Topic
ECG Monitoring and Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Reconstructing the range-normalized terminal QRS from V1 and V6 using the time-embedded 3D ECG

Alejandro Jesús Bermejo Valdés, Jessica Archer Jiménez
medRxiv
ECG Monitoring and Analysis
preprint

Reconstructing the range-normalized terminal QRS from V1 and V6 using the time-embedded 3D ECG

Alejandro Jesús Bermejo Valdés, Jessica Archer Jiménez
preprint en

Abstract

Objective. Can a fixed V1/V6 projection of the time-embedded 3D ECG estimate the final 40 ms of V2-V5 more accurately than a fitted single lead? Methods. We used simultaneous recordings from the Lobachevsky University Electrocardiography Database (LUDB), with cardiologist-annotated QRS complexes in all six chest leads. We fitted both models in 118 patients and tested them in 80 others. Root mean squared error (RMSE) is expressed in percentage points (pp) of the target lead's 10-second amplitude range. Results. In 733 test beats, patient-weighted terminal RMSE fell from 12.58 to 10.64 pp (difference 1.94 pp, 95% bootstrap confidence interval 1.30 to 2.55). Reductions were 3.23, 2.85 and 1.35 pp in V3, V4 and V5. In V2 the difference was 0.35 pp (95% interval -0.35 to 1.05). In 702 matched beats from 77 patients, the overall advantage was 2.22 pp at the automatic V1/V6 end and 1.92 pp at the annotated target end. Of 1,498 beat-lead pairs with whole-QRS correlation of at least 0.95, 28.84% still had terminal RMSE of at least 10 pp. Conclusions. A fixed V1/V6 projection improved offline estimates of relative terminal amplitude in V3-V5 without fitting the target lead in the new patient. The gain was largest in V3 and V4 and uncertain in V2. Whether a reconstructed trace preserves a clinically recognizable notch or slur remains untested.

medRxiv
Servicio Riojano de Salud (ES)
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon