How Many Days of Water? Linking Storage Adequacy, Tank Integrity, and Inspection Assurance in Strategic Potable-Water Reserves

Abstract Background. Strategic potable-water reserves in desalination-dependent countries are announced in nominal days of demand. The volume a city can actually draw during a disruption depends on dead storage, operating level and the availability of the storage units, and these are rarely reported next to the nominal figure. Methods. We built a unit-level Monte Carlo model of a strategic reserve (20 tanks in four construction batches, clustered defects, four radiography regimes, three demand tiers) and parameterised it with a two-round structured consultation of practitioners (10 experts in Round 1 on 10 November 2026; 13 in Round 2 on 11 November 2026). In Round 2 all 13 reported having discussed their answers with colleagues, so the pooled values are a consensus view and not independent judgements. Results. With the panel’s dead storage (about 17.5% of design volume) and operating level, seven nominal days equal about five usable days under total loss of supply; about 9.8–10 nominal days are needed to deliver seven usable days. For events of the ordinary size described by the panel (1–3 days) no shortfall occurred. For rare events (median 8.6 days, about 47% loss of supply capacity) the reserve was exhausted in 28–32% of runs at normal demand and in almost none at essential-level demand, although the panel judged that restrictions can be tolerated for only about four days (median). Extending radiography changed usable capacity by 0.2–1.3% of nominal volume depending on assumptions; whether this offsets its cost depends on defect severity and fragility assumptions. Conclusions. Reserve targets should state their basis and report usable days. Operating policy and event severity matter more than inspection regime for capacity, while inspection assurance mainly narrows the tail. Findings rest on a consensus panel and on parameters that remain to be verified.

Authors

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11732966/v1
Primary Topic
Infrastructure Resilience and Vulnerability Analysis
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

How Many Days of Water? Linking Storage Adequacy, Tank Integrity, and Inspection Assurance in Strategic Potable-Water Reserves

AYMAN RAMADAN
Research Square
Infrastructure Resilience and Vulnerability Analysis
preprint

How Many Days of Water? Linking Storage Adequacy, Tank Integrity, and Inspection Assurance in Strategic Potable-Water Reserves

AYMAN RAMADAN
preprint en

Abstract

Abstract Background. Strategic potable-water reserves in desalination-dependent countries are announced in nominal days of demand. The volume a city can actually draw during a disruption depends on dead storage, operating level and the availability of the storage units, and these are rarely reported next to the nominal figure. Methods. We built a unit-level Monte Carlo model of a strategic reserve (20 tanks in four construction batches, clustered defects, four radiography regimes, three demand tiers) and parameterised it with a two-round structured consultation of practitioners (10 experts in Round 1 on 10 November 2026; 13 in Round 2 on 11 November 2026). In Round 2 all 13 reported having discussed their answers with colleagues, so the pooled values are a consensus view and not independent judgements. Results. With the panel’s dead storage (about 17.5% of design volume) and operating level, seven nominal days equal about five usable days under total loss of supply; about 9.8–10 nominal days are needed to deliver seven usable days. For events of the ordinary size described by the panel (1–3 days) no shortfall occurred. For rare events (median 8.6 days, about 47% loss of supply capacity) the reserve was exhausted in 28–32% of runs at normal demand and in almost none at essential-level demand, although the panel judged that restrictions can be tolerated for only about four days (median). Extending radiography changed usable capacity by 0.2–1.3% of nominal volume depending on assumptions; whether this offsets its cost depends on defect severity and fragility assumptions. Conclusions. Reserve targets should state their basis and report usable days. Operating policy and event severity matter more than inspection regime for capacity, while inspection assurance mainly narrows the tail. Findings rest on a consensus panel and on parameters that remain to be verified.

Research Square
Clean water and sanitation
Infrastructure Resilience and Vulnerability Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon