Measurement Weighting Sets the GPS-Holdover Tolerance of PMU-Based Generator Dynamic State Estimation

Phasor measurement units (PMUs) lose GPS time and enter holdover on a local oscillator, whose drift rotates every reported phasor. How long holdover can last before generator dynamic state estimation degrades remains unquantified. We study an extended Kalman filter on the IEEE 39-bus system against an ANDES simulation with stochastic loads and field-level PMU noise, under a pre-specified analysis plan. We derive a closed form for the share of PMU phase drift reaching rotor-angle estimates; it matched all 21 tested cases within 3%. This share depends on the filter’s weighting of active power against voltage angle. With noise variances calibrated to the innovations, a drifting PMU passed up to 3.0 times its phase error into the rotor angles. With compensated quartz, the error reached 0.005 rad (0.29°) after 3.5–11 min, before the PMU’s own angle error (14.7 min). Weighting power more heavily cut the pass-through 13–32-fold at the simulated locations and had the lower no-drift error (2.4 against 3.2 mrad). A clock-aware filter removed drift at some cost in ambient accuracy; with power measurements, an innovation test detected every simulated single-PMU drift without holdover flags. Holdover tolerance depends on the estimator’s weighting as much as on the oscillator.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-17
DOI
https://doi.org/10.20944/preprints202611.1646.v1
Primary Topic
Power System Optimization and Stability
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Measurement Weighting Sets the GPS-Holdover Tolerance of PMU-Based Generator Dynamic State Estimation

Luiz G. P. Marcondes, Robson Celso Pires
Preprints.org
Power System Optimization and Stability
preprint

Measurement Weighting Sets the GPS-Holdover Tolerance of PMU-Based Generator Dynamic State Estimation

Luiz G. P. Marcondes, Robson Celso Pires
preprint en

Abstract

Phasor measurement units (PMUs) lose GPS time and enter holdover on a local oscillator, whose drift rotates every reported phasor. How long holdover can last before generator dynamic state estimation degrades remains unquantified. We study an extended Kalman filter on the IEEE 39-bus system against an ANDES simulation with stochastic loads and field-level PMU noise, under a pre-specified analysis plan. We derive a closed form for the share of PMU phase drift reaching rotor-angle estimates; it matched all 21 tested cases within 3%. This share depends on the filter’s weighting of active power against voltage angle. With noise variances calibrated to the innovations, a drifting PMU passed up to 3.0 times its phase error into the rotor angles. With compensated quartz, the error reached 0.005 rad (0.29°) after 3.5–11 min, before the PMU’s own angle error (14.7 min). Weighting power more heavily cut the pass-through 13–32-fold at the simulated locations and had the lower no-drift error (2.4 against 3.2 mrad). A clock-aware filter removed drift at some cost in ambient accuracy; with power measurements, an innovation test detected every simulated single-PMU drift without holdover flags. Holdover tolerance depends on the estimator’s weighting as much as on the oscillator.

Preprints.org
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon