Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China

Wellhead heating is indispensable for high-pressure gas wells because the temperature drop caused by two-stage throttling brings the gas close to the hydrate formation temperature. The existing air-source heat pump (ASHP)-based heating system of a gas field in Northwestern China consumes 1,314,000 kWh of electricity every year, and its performance degrades severely at ambient temperatures down to −25 °C. To reduce the energy consumption due to wellhead heating, a solar-assisted air-source heat pump (SA-ASHP) system was proposed and investigated in this work. Two solar collector technologies, namely dish solar collectors and evacuated-tube collectors, were coupled with the ASHP, and TRNSYS models of both configurations were established together with a reference model of the existing ASHP system. The ASHP model was validated against field measurements with the part-load factor, and the deviation between the simulated and the metered August electricity consumption of the three wells is only 4.43%. The collector area, the storage tank volume and the heat-transfer-oil flow rates were then optimized with the life cycle cost as the objective under the constraint that the annual heating guarantee rate is not lower than 99.5%. The results show that the optimal dish collector scheme consists of eight collectors (800 m2) and an 80 m3 storage tank, which reduces the annual electricity consumption to 294,817 kWh, which is 22.4% of the direct electric heating scheme, raises the system COP to 4.46, saves 39.6 × 104 CNY of electricity cost per year and achieves the highest return on investment of 4.31%. The optimal evacuated-tube collector scheme requires 800 m2 of collector area and a 45 m3 storage tank and gives a return on investment of 4.05%. The SA-ASHP with dish collector scheme is therefore recommended as the most energy-efficient heating scheme, with the highest return on investment, for the studied gas field.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-11-17
DOI
https://doi.org/10.3390/pr14223692
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China

binyuan Rao, Xiaoling Chen, Yongxing Zhang, Yingjie Li et al.
3 links
Processes
Solar Thermal and Photovoltaic Systems
article

Performance and Optimization of a Solar-Assisted Air-Source Heat Pump System for Wellhead Heating in a High-Pressure Gas Field of Northwestern China

binyuan Rao, Xiaoling Chen, Yongxing Zhang, Yingjie Li, Naipeng Liu, Guangdan Zhao, Qin Liu, Yongle Bai
article en

Abstract

Wellhead heating is indispensable for high-pressure gas wells because the temperature drop caused by two-stage throttling brings the gas close to the hydrate formation temperature. The existing air-source heat pump (ASHP)-based heating system of a gas field in Northwestern China consumes 1,314,000 kWh of electricity every year, and its performance degrades severely at ambient temperatures down to −25 °C. To reduce the energy consumption due to wellhead heating, a solar-assisted air-source heat pump (SA-ASHP) system was proposed and investigated in this work. Two solar collector technologies, namely dish solar collectors and evacuated-tube collectors, were coupled with the ASHP, and TRNSYS models of both configurations were established together with a reference model of the existing ASHP system. The ASHP model was validated against field measurements with the part-load factor, and the deviation between the simulated and the metered August electricity consumption of the three wells is only 4.43%. The collector area, the storage tank volume and the heat-transfer-oil flow rates were then optimized with the life cycle cost as the objective under the constraint that the annual heating guarantee rate is not lower than 99.5%. The results show that the optimal dish collector scheme consists of eight collectors (800 m2) and an 80 m3 storage tank, which reduces the annual electricity consumption to 294,817 kWh, which is 22.4% of the direct electric heating scheme, raises the system COP to 4.46, saves 39.6 × 104 CNY of electricity cost per year and achieves the highest return on investment of 4.31%. The optimal evacuated-tube collector scheme requires 800 m2 of collector area and a 45 m3 storage tank and gives a return on investment of 4.05%. The SA-ASHP with dish collector scheme is therefore recommended as the most energy-efficient heating scheme, with the highest return on investment, for the studied gas field.

ProcessesVol. 14(22)
China University of Petroleum, Beijing (CN), Karamay Central Hospital of Xinjiang (CN), PetroChina Xinjiang Oilfield Company (China) (CN)
Affordable and clean energy, Climate action
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon