A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Finite detector resolution can bias resonance parameters and fit fractions extracted from amplitude analyses. We present the paired Monte Carlo intensity-ratio method for incorporating resolution effects into amplitude analysis. The method uses ratios of reference intensities evaluated at paired truth-level and reconstructed kinematics to reweight the Monte Carlo normalization and approximately account for detector resolution. A resampling study of simulated $D^+\to K^+π^+π^-π^0$ decays shows that the method substantially reduces resolution-induced shifts in fitted resonance widths. Likelihood evaluation uses intensity calculations and normalization sums, avoiding a response convolution at each data event.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-16
DOI
https://doi.org/10.48550/arxiv.2611.20508
Primary Topic
Particle physics theoretical and experimental studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Liping Yang, Liaoyuan Dong, Bai-Cian Ke, Minggang Zhao et al.
arXiv (Cornell University)
Particle physics theoretical and experimental studies
preprint

A Paired Monte Carlo Intensity-Ratio Method for Incorporating Detector Resolution in Amplitude Analysis

Liping Yang, Liaoyuan Dong, Bai-Cian Ke, Minggang Zhao, Zhenxuan Li
preprint en

Abstract

Finite detector resolution can bias resonance parameters and fit fractions extracted from amplitude analyses. We present the paired Monte Carlo intensity-ratio method for incorporating resolution effects into amplitude analysis. The method uses ratios of reference intensities evaluated at paired truth-level and reconstructed kinematics to reweight the Monte Carlo normalization and approximately account for detector resolution. A resampling study of simulated $D^+\to K^+π^+π^-π^0$ decays shows that the method substantially reduces resolution-induced shifts in fitted resonance widths. Likelihood evaluation uses intensity calculations and normalization sums, avoiding a response convolution at each data event.

arXiv (Cornell University)
Particle physics theoretical and experimental studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon