Data-Driven Respiratory Motion Correction in 18 F-FDG PET for Cardiac Sarcoidosis: A Location-Dependent Phantom Study

Respiratory motion (RM) may affect quantitative accuracy in 18F-FDG PET for cardiac sarcoidosis (CS). Here, we evaluated the location-dependent effects of RM and RM correction (RMC) using a CS phantom with focal myocardial lesions. Methods: CS lesions were simulated by coin-shaped inserts attached to the anterior, septal, and inferior walls of a cardiac phantom. PET data were acquired under static conditions and simulated RM conditions with motion amplitudes of 10, 20, and 30 mm. RMC images were generated using data-driven respiratory gating. Both SUVmax and SUVmean were measured, and percentage changes relative to static images were calculated. Results: RM caused progressive underestimation of SUV with increasing motion amplitude. The degree of SUV reduction differed with lesion location. With motion of ±15 mm, SUVmax decreased by 44% in anterior, 39% in inferior, and 27% in septal walls. With motion correction of ±15 mm, SUVmax reductions improved to 39% in anterior, 23% in inferior, and 6% in septal walls, with the greatest improvement observed in the latter. SUVmean showed trends similar to those of SUVmax. Conclusion: RM causes a region-dependent decrease in the quantitative accuracy of 18F-FDG PET for CS lesions. Although RMC decreased SUV underestimation, a substantial underestimation remained at larger motion amplitudes. Therefore, both RM and lesion location are relevant factors to consider in quantitative PET evaluations for CS.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine Technology
Published
2026-11-17
DOI
https://doi.org/10.2967/jnmt.126.273156
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Data-Driven Respiratory Motion Correction in 18 F-FDG PET for Cardiac Sarcoidosis: A Location-Dependent Phantom Study

Ayano Onoma, Takayuki Shibutani, Masahisa Onoguchi, Eiji Ishikawa et al.
1 links
Journal of Nuclear Medicine Technology
Medical Imaging Techniques and Applications
article

Data-Driven Respiratory Motion Correction in 18 F-FDG PET for Cardiac Sarcoidosis: A Location-Dependent Phantom Study

Ayano Onoma, Takayuki Shibutani, Masahisa Onoguchi, Eiji Ishikawa, Hajime Ichikawa
article en

Abstract

Respiratory motion (RM) may affect quantitative accuracy in 18F-FDG PET for cardiac sarcoidosis (CS). Here, we evaluated the location-dependent effects of RM and RM correction (RMC) using a CS phantom with focal myocardial lesions. Methods: CS lesions were simulated by coin-shaped inserts attached to the anterior, septal, and inferior walls of a cardiac phantom. PET data were acquired under static conditions and simulated RM conditions with motion amplitudes of 10, 20, and 30 mm. RMC images were generated using data-driven respiratory gating. Both SUVmax and SUVmean were measured, and percentage changes relative to static images were calculated. Results: RM caused progressive underestimation of SUV with increasing motion amplitude. The degree of SUV reduction differed with lesion location. With motion of ±15 mm, SUVmax decreased by 44% in anterior, 39% in inferior, and 27% in septal walls. With motion correction of ±15 mm, SUVmax reductions improved to 39% in anterior, 23% in inferior, and 6% in septal walls, with the greatest improvement observed in the latter. SUVmean showed trends similar to those of SUVmax. Conclusion: RM causes a region-dependent decrease in the quantitative accuracy of 18F-FDG PET for CS lesions. Although RMC decreased SUV underestimation, a substantial underestimation remained at larger motion amplitudes. Therefore, both RM and lesion location are relevant factors to consider in quantitative PET evaluations for CS.

Journal of Nuclear Medicine Technology
Kanazawa University (JP), Kanazawa Medical University (JP), Kanazawa Medical Center (JP), Yokohama City University Hospital (JP), Niigata University of Health and Welfare (JP), Yokohama City University (JP)
Good health and well-being
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon