Experimental assessment of active and passive cooling configurations for photovoltaic modules under outdoor conditions

This study experimentally evaluated front-surface water-film cooling and rear-mounted aluminum heat sinks for polycrystalline photovoltaic modules under outdoor conditions. Two 100-Wp modules of the same model were monitored from November 2025 to March 2026, with temperature, voltage, and current recorded at 1-min intervals. During the representative active test, the maximum backsheet temperature was 42.0 °C for the water-film configuration and 50.5 °C for the reference module, a difference of 8.5 °C. Across nine monitoring days, differences between their daily maximum temperatures ranged from 8.5 °C to 18.96 °C. After subtracting 22.89 Wh of pump consumption, excluding power-supply losses and control-system consumption, the active configuration delivered 475.05 Wh of net electrical energy, compared with 438.06 Wh for the reference, corresponding to a difference of 8.44%. During the representative passive test, the heat-sink configuration showed a maximum backsheet temperature 1.50 °C below the reference and a daily electrical-energy difference of 1.70%, smaller than its reported expanded uncertainty. The investigated module operated with maximum power point tracking, while the reference used a fixed resistive load. Consequently, the electrical differences reflect both cooling and electrical load management and cannot be attributed exclusively to cooling. The water-film configuration showed a larger temperature reduction under its test conditions, but the active and passive results were obtained on different days and do not establish a comparison under matched environmental conditions.

Authors

Institutions

Publication Details

Journal
Frontiers in Thermal Engineering
Published
2026-11-17
DOI
https://doi.org/10.3389/fther.2026.1970235
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental assessment of active and passive cooling configurations for photovoltaic modules under outdoor conditions

Ênio Pedone Bandarra Filho, Gleyzer Martins, Lucas Carvalho Martins, Yeyner Alveiro Carrillo Pabon et al.
1 links
Frontiers in Thermal Engineering
Solar Thermal and Photovoltaic Systems
article

Experimental assessment of active and passive cooling configurations for photovoltaic modules under outdoor conditions

Ênio Pedone Bandarra Filho, Gleyzer Martins, Lucas Carvalho Martins, Yeyner Alveiro Carrillo Pabon, João Rodrigo Andrade
article en

Abstract

This study experimentally evaluated front-surface water-film cooling and rear-mounted aluminum heat sinks for polycrystalline photovoltaic modules under outdoor conditions. Two 100-Wp modules of the same model were monitored from November 2025 to March 2026, with temperature, voltage, and current recorded at 1-min intervals. During the representative active test, the maximum backsheet temperature was 42.0 °C for the water-film configuration and 50.5 °C for the reference module, a difference of 8.5 °C. Across nine monitoring days, differences between their daily maximum temperatures ranged from 8.5 °C to 18.96 °C. After subtracting 22.89 Wh of pump consumption, excluding power-supply losses and control-system consumption, the active configuration delivered 475.05 Wh of net electrical energy, compared with 438.06 Wh for the reference, corresponding to a difference of 8.44%. During the representative passive test, the heat-sink configuration showed a maximum backsheet temperature 1.50 °C below the reference and a daily electrical-energy difference of 1.70%, smaller than its reported expanded uncertainty. The investigated module operated with maximum power point tracking, while the reference used a fixed resistive load. Consequently, the electrical differences reflect both cooling and electrical load management and cannot be attributed exclusively to cooling. The water-film configuration showed a larger temperature reduction under its test conditions, but the active and passive results were obtained on different days and do not establish a comparison under matched environmental conditions.

Frontiers in Thermal EngineeringVol. 6
Prince Mohammad bin Fahd University (SA), Universidade do Estado de Minas Gerais (BR), Universidade Federal de Uberlândia (BR)
Affordable and clean energy, Climate action
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon