The Cost of Inaction: Ten Years of Neuraxial Misconnection Tragedies, 2014 to 2024

A tubing misconnection occurs when a delivery system, such as an intravenous line, tube, syringe, or catheter, is accidentally connected to a physiologically incompatible system. Misconnections can result in patient harm and death and have been reported for decades. The high-leverage risk mitigation strategy of using nonuniversal small-bore connectors to prevent connection to another route, system, or device is available. However, a recent survey conducted by clinical advisors working in coordination with the Global Engineered Device Supplier Association (GEDSA) found significant persistence of misconnection events. This paper details the methods and results of a systematic search and review of more recent (2014 to 2024) peer-reviewed literature, grey literature, and news stories to catalog cases of neuraxial misconnections. The search identified 95 records that detailed 110 cases of neuraxial misconnection. Twenty-three (20.9%) resulted in death, and 72 (65.5%) resulted in patient harm. Only 9 (8.2%) did not result in harm. A substantial number of cases occurred in the perioperative setting and, in particular, during labor and delivery. There were 6 medications associated with patient death. These medications were also associated with substantial patient harm. By providing information about the setting, type of error, medications involved, and level of harm, this paper describes misconnection events, explores contributing factors to the medical error, and provides proposed solutions to prevent misconnections. The ISMP Hierarchy of Effectiveness of Risk-Reduction Strategies is used to present layered and leveraged strategies to minimize the risk of these events reaching a patient.

Authors

Institutions

Publication Details

Journal
Journal of Patient Safety
Published
2026-11-17
DOI
https://doi.org/10.1097/pts.0000000000001609
Primary Topic
Patient Safety and Medication Errors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Cost of Inaction: Ten Years of Neuraxial Misconnection Tragedies, 2014 to 2024

Nina Smith, Sonya E. Fogg, Kelsey Koym, Stacie J Ethington et al.
Journal of Patient Safety
Patient Safety and Medication Errors
article

The Cost of Inaction: Ten Years of Neuraxial Misconnection Tragedies, 2014 to 2024

Nina Smith, Sonya E. Fogg, Kelsey Koym, Stacie J Ethington, Debora Simmons, Amanda Volpe
article en

Abstract

A tubing misconnection occurs when a delivery system, such as an intravenous line, tube, syringe, or catheter, is accidentally connected to a physiologically incompatible system. Misconnections can result in patient harm and death and have been reported for decades. The high-leverage risk mitigation strategy of using nonuniversal small-bore connectors to prevent connection to another route, system, or device is available. However, a recent survey conducted by clinical advisors working in coordination with the Global Engineered Device Supplier Association (GEDSA) found significant persistence of misconnection events. This paper details the methods and results of a systematic search and review of more recent (2014 to 2024) peer-reviewed literature, grey literature, and news stories to catalog cases of neuraxial misconnections. The search identified 95 records that detailed 110 cases of neuraxial misconnection. Twenty-three (20.9%) resulted in death, and 72 (65.5%) resulted in patient harm. Only 9 (8.2%) did not result in harm. A substantial number of cases occurred in the perioperative setting and, in particular, during labor and delivery. There were 6 medications associated with patient death. These medications were also associated with substantial patient harm. By providing information about the setting, type of error, medications involved, and level of harm, this paper describes misconnection events, explores contributing factors to the medical error, and provides proposed solutions to prevent misconnections. The ISMP Hierarchy of Effectiveness of Risk-Reduction Strategies is used to present layered and leveraged strategies to minimize the risk of these events reaching a patient.

Journal of Patient Safety
Hartford Hospital (US), Texas Medical Center (US), Institute for Safe Medication Practices (US), Texas Medical Center Library (US), University of Houston (US)
Good health and well-being
Patient Safety and Medication Errors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon