Deterministic projection selection for Limited-View Computed Tomography
Abstract In Limited-View Computed Tomography (LVCT), one restricts the number of projection angles (or views) for data reduction, which has many implications, especially in medical domain. In most of the existing works on LVCT, the views are sampled randomly or in equi-spaced manner, which makes the sampling process oblivion to the image reconstruction solvers. Motivated by this gap between the sampling strategy and the image reconstruction solvers, we propose a deterministic way of finding an optimal set of views for LVCT using block-sparse optimization problem. The proposed methodology is tied to a selection of Radon sub-matrix possessing low total coherence which is desired for sparsity-based CT image reconstruction. We demonstrate efficacy of the proposed deterministic LVCT in recovering CT images.
Authors
- Pradip Sasmal (ORCID: https://orcid.org/0000-0003-0111-2509)
- Munnu Sonkar (ORCID: https://orcid.org/0000-0002-3543-2626)
- CS Sastry
Institutions
- Indian Institute of Technology Jodhpur (IN)
- Indian Institute of Technology Hyderabad (IN)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-17
- DOI
- https://doi.org/10.21203/rs.3.rs-8662735/v1
- Primary Topic
- Sparse and Compressive Sensing Techniques
- Type
- preprint