Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows

Background/Objectives: Standing full-length radiographs support pediatric lower-limb deformity assessment and preoperative evaluation. Manual alignment measurement is time-consuming and observer-dependent. We evaluated an author-developed artificial intelligence (AI) system that provides automated measurements and reviewable anatomical landmarks. Methods: This single-center retrospective study used 240 training, 80 validation, and 80 independent test radiographs, partitioned by patient. The test cohort included 80 patients (22 pediatric) and 160 limbs (44 pediatric). Six alignment angles were assessed against the mean of three measurements by an experienced deformity surgeon. Fully automated AI, unassisted physician workflows, and an AI-assisted resident workflow were compared using intraclass correlation coefficients (ICCs), mean absolute error (MAE), Bland–Altman analysis, and measurement time. Results: Fully automated AI achieved ICCs of 0.728–0.966 and MAEs of 0.52–1.26° across the six angles. In pediatric limbs, average-measure ICCs were 0.936–0.975 for five major alignment angles; the single-measure ICC for joint line convergence angle was 0.825. For the resident evaluated, AI-assisted MAEs were 0.57–1.41°, compared with 1.22–6.83° without assistance. Mean measurement time per radiograph was 2.7 ± 0.4 s for fully automated AI and 10.5 ± 3.4 s for physician-reviewed AI, compared with 77.9–100.5 s for unassisted physician workflows. Conclusions: The AI system provided angle-specific agreement with the expert reference and substantially faster measurement than unassisted workflows. Physician-supervised AI was associated with lower measurement error for the resident evaluated. The findings suggest potential utility as a physician-reviewed measurement aid. Pediatric results are encouraging and should be interpreted as descriptive evidence within the evaluated age range.

Authors

Institutions

Publication Details

Journal
Children
Published
2026-11-17
DOI
https://doi.org/10.3390/children13111601
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows

Halil İbrahim Balcı, Yavuz Sağlam, Cengiz Şen, Alper Şükrü Kendirci et al.
3 links
Children
Artificial Intelligence in Healthcare and Education
article

Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows

Halil İbrahim Balcı, Yavuz Sağlam, Cengiz Şen, Alper Şükrü Kendirci, İsmail Tarık Atasoy, Oğuzhan Günbatar, Nurol Efe Alptekin
article en

Abstract

Background/Objectives: Standing full-length radiographs support pediatric lower-limb deformity assessment and preoperative evaluation. Manual alignment measurement is time-consuming and observer-dependent. We evaluated an author-developed artificial intelligence (AI) system that provides automated measurements and reviewable anatomical landmarks. Methods: This single-center retrospective study used 240 training, 80 validation, and 80 independent test radiographs, partitioned by patient. The test cohort included 80 patients (22 pediatric) and 160 limbs (44 pediatric). Six alignment angles were assessed against the mean of three measurements by an experienced deformity surgeon. Fully automated AI, unassisted physician workflows, and an AI-assisted resident workflow were compared using intraclass correlation coefficients (ICCs), mean absolute error (MAE), Bland–Altman analysis, and measurement time. Results: Fully automated AI achieved ICCs of 0.728–0.966 and MAEs of 0.52–1.26° across the six angles. In pediatric limbs, average-measure ICCs were 0.936–0.975 for five major alignment angles; the single-measure ICC for joint line convergence angle was 0.825. For the resident evaluated, AI-assisted MAEs were 0.57–1.41°, compared with 1.22–6.83° without assistance. Mean measurement time per radiograph was 2.7 ± 0.4 s for fully automated AI and 10.5 ± 3.4 s for physician-reviewed AI, compared with 77.9–100.5 s for unassisted physician workflows. Conclusions: The AI system provided angle-specific agreement with the expert reference and substantially faster measurement than unassisted workflows. Physician-supervised AI was associated with lower measurement error for the resident evaluated. The findings suggest potential utility as a physician-reviewed measurement aid. Pediatric results are encouraging and should be interpreted as descriptive evidence within the evaluated age range.

ChildrenVol. 13(11)
Istanbul University (TR)
Good health and well-being
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon