Enhanced Power-quality Regulation in PV-integrated Systems Using Adaptive Reduced-set Horizon-2 FCS-MPC Systems

The increasing use of renewable generation and power-electronic loads makes simultaneous voltage and current power-quality regulation important in distribution systems.Unified Power Quality Conditioners (UPQCs) can address both disturbance types, but conventional control and full finite-state predictive searches may face tracking and computational trade-offs under changing operating conditions.This study presents an Adaptive Reduced-Set Horizon-2 Finite-Control-Set Model Predictive Control (RS-H2 FCS-MPC) strategy for a matrix-converter UPQC integrated with photovoltaic distributed generation (PV-DG).The controller combines 27-state discrete matrix conversion, reduced second-step prediction, adaptive magnitude restoration, switching-transition and common-mode-voltage penalties, PV power feedforward, positive-sequence synchronization, and a clean-grid deadband.Evaluation uses SEED-PQD-v1 containing 17 power-quality classes and 17,000 signals, with 100 signals reserved for parameter tuning and the remaining 16,900 used for held-out evaluation.Under Protocol A, the six-condition held-out composite evaluation profile comprising Pure Sinusoidal, Sag, Swell, Harmonics, Sag with Harmonics, and Swell with Harmonics conditions, the proposed controller obtains 0.5487% voltage total harmonic distortion (THD), 0.8149% current THD, a power factor of 0.9508, and a power-quality index of 3.9362.The full 17-class assessment is reported separately.Clean-grid operation produces zero series injection and 0% voltage THD.Paired Wilcoxon tests with Holm correction on a 25-trial matched subset support the reported controller differences within the selected disturbance conditions.The results support reduced-set predictive control for compensation under the evaluated balanced multi-disturbance conditions, while the interruption case remains energy-limited without storage.

Authors

Institutions

Publication Details

Journal
International journal of intelligent engineering and systems
Published
2026-11-17
DOI
https://doi.org/10.22266/ijies2026.1231.15
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Enhanced Power-quality Regulation in PV-integrated Systems Using Adaptive Reduced-set Horizon-2 FCS-MPC Systems

Sangamesh G. Sakri, Naveen G
1 links
International journal of intelligent engineering and systems
Power Quality and Harmonics
article

Enhanced Power-quality Regulation in PV-integrated Systems Using Adaptive Reduced-set Horizon-2 FCS-MPC Systems

Sangamesh G. Sakri, Naveen G
article en

Abstract

The increasing use of renewable generation and power-electronic loads makes simultaneous voltage and current power-quality regulation important in distribution systems.Unified Power Quality Conditioners (UPQCs) can address both disturbance types, but conventional control and full finite-state predictive searches may face tracking and computational trade-offs under changing operating conditions.This study presents an Adaptive Reduced-Set Horizon-2 Finite-Control-Set Model Predictive Control (RS-H2 FCS-MPC) strategy for a matrix-converter UPQC integrated with photovoltaic distributed generation (PV-DG).The controller combines 27-state discrete matrix conversion, reduced second-step prediction, adaptive magnitude restoration, switching-transition and common-mode-voltage penalties, PV power feedforward, positive-sequence synchronization, and a clean-grid deadband.Evaluation uses SEED-PQD-v1 containing 17 power-quality classes and 17,000 signals, with 100 signals reserved for parameter tuning and the remaining 16,900 used for held-out evaluation.Under Protocol A, the six-condition held-out composite evaluation profile comprising Pure Sinusoidal, Sag, Swell, Harmonics, Sag with Harmonics, and Swell with Harmonics conditions, the proposed controller obtains 0.5487% voltage total harmonic distortion (THD), 0.8149% current THD, a power factor of 0.9508, and a power-quality index of 3.9362.The full 17-class assessment is reported separately.Clean-grid operation produces zero series injection and 0% voltage THD.Paired Wilcoxon tests with Holm correction on a 25-trial matched subset support the reported controller differences within the selected disturbance conditions.The results support reduced-set predictive control for compensation under the evaluated balanced multi-disturbance conditions, while the interruption case remains energy-limited without storage.

International journal of intelligent engineering and systemsVol. 19(12)
Visvesvaraya Technological University (IN)
Affordable and clean energy, Industry, innovation and infrastructure
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon