Multivariate calibration for on-line spectroscopic monitoring of nuclear process streams: a review from fuel reprocessing to fusion tritium plants

Abstract On-line optical spectroscopy can monitor nuclear process streams only while its calibration remains valid. No review has covered both the fission and fusion fuel cycles or graded how far monitoring is integrated into the process. We define a six-level integration ladder (L0–L5) and apply it to 130 studies. Over half (69) stop at an on-line probe with a static model validated on simulants; 23 reach validation on real material with drift addressed, or closure of a control loop. Higher levels are associated with validation on real material rather than with the calibration algorithm. The two literatures hold complementary calibration practices.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2026-11-17
DOI
https://doi.org/10.1007/s10967-026-11306-z
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multivariate calibration for on-line spectroscopic monitoring of nuclear process streams: a review from fuel reprocessing to fusion tritium plants

Ronny Rives, M. Suliany Rodríguez-Barrios
3 links
Journal of Radioanalytical and Nuclear Chemistry
Spectroscopy and Chemometric Analyses
article

Multivariate calibration for on-line spectroscopic monitoring of nuclear process streams: a review from fuel reprocessing to fusion tritium plants

Ronny Rives, M. Suliany Rodríguez-Barrios
article en

Abstract

Abstract On-line optical spectroscopy can monitor nuclear process streams only while its calibration remains valid. No review has covered both the fission and fusion fuel cycles or graded how far monitoring is integrated into the process. We define a six-level integration ladder (L0–L5) and apply it to 130 studies. Over half (69) stop at an on-line probe with a static model validated on simulants; 23 reach validation on real material with drift addressed, or closure of a control loop. Higher levels are associated with validation on real material rather than with the calibration algorithm. The two literatures hold complementary calibration practices.

Journal of Radioanalytical and Nuclear Chemistry
Universitat Politècnica de Catalunya (ES)
Universitat Politècnica de Catalunya
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon