Study on the long-term stability and consistency of realizations of the triple point of carbon dioxide

Abstract The triple point of carbon dioxide (CO 2 TP) is one promising candidate for the alternative of the mercury triple point (Hg TP). The long-term stability and consistency realizing the CO 2 TP has the essential importance on the feasibility of the alternative. The experimental study described here addresses this point. In order to exclude unessential influences, we selected a single thermometer of high stability to be used in this work, spanning four years. We have constructed three cells for this study. During a four-years span, the realization of the CO 2 TP using the first cell demonstrates a long-term stability of 0.04 mK and a standard deviation of 0.04 mK. The realizations by the other two cells differ from that of the first cell by 0.02 mK and 0.08 mK, respectively. The standard deviations of measurement are less than 0.065 mK at F=0.5, and 0.099 mK at F=1.0 for the other two cells. The regular weighing of the cells shows minor leaks from the sample in the cell. The cumulative leakage of the first cell in the four-years span is 52 g. Nevertheless, the long-term stability exhibits no systematic drift and independence of sample mass leakage. In summary, this work demonstrates a perspective of long-term stability and consistency with the realizations of the CO 2 TP.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2026-11-17
DOI
https://doi.org/10.1088/1681-7575/aec2ef
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Study on the long-term stability and consistency of realizations of the triple point of carbon dioxide

Jintao Zhang, X. J. Feng, Yu Liang
Metrologia
Scientific Measurement and Uncertainty Evaluation
article

Study on the long-term stability and consistency of realizations of the triple point of carbon dioxide

Jintao Zhang, X. J. Feng, Yu Liang
article en

Abstract

Abstract The triple point of carbon dioxide (CO 2 TP) is one promising candidate for the alternative of the mercury triple point (Hg TP). The long-term stability and consistency realizing the CO 2 TP has the essential importance on the feasibility of the alternative. The experimental study described here addresses this point. In order to exclude unessential influences, we selected a single thermometer of high stability to be used in this work, spanning four years. We have constructed three cells for this study. During a four-years span, the realization of the CO 2 TP using the first cell demonstrates a long-term stability of 0.04 mK and a standard deviation of 0.04 mK. The realizations by the other two cells differ from that of the first cell by 0.02 mK and 0.08 mK, respectively. The standard deviations of measurement are less than 0.065 mK at F=0.5, and 0.099 mK at F=1.0 for the other two cells. The regular weighing of the cells shows minor leaks from the sample in the cell. The cumulative leakage of the first cell in the four-years span is 52 g. Nevertheless, the long-term stability exhibits no systematic drift and independence of sample mass leakage. In summary, this work demonstrates a perspective of long-term stability and consistency with the realizations of the CO 2 TP.

Metrologia
National Institute of Metrology (CN)
Climate action
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon