Automated Infant Wellness Reporting Using Saturation of Oxygen (SpO2) Histogram and Frequency of Desaturation in Neonates: A Feasibility Study

Background: Continuous physiologic monitoring produces large volumes of high-resolution data in neonatal intensive care units (NICUs), but clinicians do not rou-tinely convert these data into automated longitudinal assessments of infant physiologic wellness. Objective: To evaluate the technical and implementation feasibility of an in-tegrated digital platform (iNICU) incorporating the digital Review of Oxygen Saturation and Events (dROSE) algorithm for automated daily infant wellness reporting. Methods: We conducted a prospective, three-phase feasibility study in a quaternary NICU using seven instrumented beds. We collected heart rate, respiratory rate, and oxygen saturation data at 1 Hz. dROSE applied predefined oxygen saturation and desaturation-frequency thresholds to classify daily physiologic wellness as stable, watcher, or unstable. We evaluated pre-specified feasibility criteria, compared dROSE classifications with inde-pendent bedside nurse assessments, descriptively examined subsequent clinical dete-rioration and improvement events, and assessed requirements for broader deployment using Technology Readiness Level (TRL) criteria. Results: Fifty-nine infants and 25 nurses participated. Physiologic data capture completeness was 86%, below the pre-specified 90% threshold. Following technical refinement, concordance with the reference monitoring system reached 92% for desaturation events, 91% for bradycardia events, and 90% for oxygen saturation histograms. The system auto-generated 451 eligible daily infant wellness reports. Among 126 paired assessments from 18 infants, exact agreement be-tween dROSE and bedside nurse classifications was 49.2%, with dROSE assigning a higher-severity category in 45.2%. Subsequent deterioration-event rates across nurse-assigned stable, watcher, and unstable states were 3.2, 13.2, and 15.0 events per 10 observation-days, compared with 1.4, 4.0, and 3.1 following the corresponding dROSE classifications. The team created a roadmap for broader deployment but did not carry out testing at full-unit scale. The team achieved TRL 6 with the integrated system and con-sidered it to be progressing toward TRL 7. Conclusions: The iNICU-dROSE system demonstrated pilot-scale feasibility for automated physiologic data acquisition, pro-cessing, and reporting, but limitations in acquisition reliability, high-volume reporting, and clinical concordance remain. The TRL-based assessment supports a “CONDITIONAL GO” for continued technical development, outcome-based refinement and validation of the wellness-classification approach, and targeted retesting before broader operational or clinical implementation

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-16
DOI
https://doi.org/10.20944/preprints202611.1582.v1
Primary Topic
Healthcare Technology and Patient Monitoring
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Automated Infant Wellness Reporting Using Saturation of Oxygen (SpO2) Histogram and Frequency of Desaturation in Neonates: A Feasibility Study

Matthias Görges, Sandesh P. Shivananda, Harpreet Singh, Jonathan Wong et al.
Preprints.org
Healthcare Technology and Patient Monitoring
preprint

Automated Infant Wellness Reporting Using Saturation of Oxygen (SpO2) Histogram and Frequency of Desaturation in Neonates: A Feasibility Study

Matthias Görges, Sandesh P. Shivananda, Harpreet Singh, Jonathan Wong, Kanekal S. Gautham
preprint en

Abstract

Background: Continuous physiologic monitoring produces large volumes of high-resolution data in neonatal intensive care units (NICUs), but clinicians do not rou-tinely convert these data into automated longitudinal assessments of infant physiologic wellness. Objective: To evaluate the technical and implementation feasibility of an in-tegrated digital platform (iNICU) incorporating the digital Review of Oxygen Saturation and Events (dROSE) algorithm for automated daily infant wellness reporting. Methods: We conducted a prospective, three-phase feasibility study in a quaternary NICU using seven instrumented beds. We collected heart rate, respiratory rate, and oxygen saturation data at 1 Hz. dROSE applied predefined oxygen saturation and desaturation-frequency thresholds to classify daily physiologic wellness as stable, watcher, or unstable. We evaluated pre-specified feasibility criteria, compared dROSE classifications with inde-pendent bedside nurse assessments, descriptively examined subsequent clinical dete-rioration and improvement events, and assessed requirements for broader deployment using Technology Readiness Level (TRL) criteria. Results: Fifty-nine infants and 25 nurses participated. Physiologic data capture completeness was 86%, below the pre-specified 90% threshold. Following technical refinement, concordance with the reference monitoring system reached 92% for desaturation events, 91% for bradycardia events, and 90% for oxygen saturation histograms. The system auto-generated 451 eligible daily infant wellness reports. Among 126 paired assessments from 18 infants, exact agreement be-tween dROSE and bedside nurse classifications was 49.2%, with dROSE assigning a higher-severity category in 45.2%. Subsequent deterioration-event rates across nurse-assigned stable, watcher, and unstable states were 3.2, 13.2, and 15.0 events per 10 observation-days, compared with 1.4, 4.0, and 3.1 following the corresponding dROSE classifications. The team created a roadmap for broader deployment but did not carry out testing at full-unit scale. The team achieved TRL 6 with the integrated system and con-sidered it to be progressing toward TRL 7. Conclusions: The iNICU-dROSE system demonstrated pilot-scale feasibility for automated physiologic data acquisition, pro-cessing, and reporting, but limitations in acquisition reliability, high-volume reporting, and clinical concordance remain. The TRL-based assessment supports a “CONDITIONAL GO” for continued technical development, outcome-based refinement and validation of the wellness-classification approach, and targeted retesting before broader operational or clinical implementation

Preprints.org
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon