Extensor pollicis longus tendon reconstruction with palmaris longus tendon graft due to attritional rupture by screws, K-wires, and intramedullary nails

Introduction : Extensor pollicis longus (EPL) tendon rupture is a significant complication following fracture fixation around the distal radius and forearm. The tendon is particularly susceptible to attritional wear caused by prominent screws, protruding Kirschner wires (K-wires), dorsal cortical penetration, and prominent intramedullary nail entry points. Rupture results in profound loss of thumb extension, reduced pinch strength, impaired dexterity, and functional disability. Palmaris longus (PL) tendon graft reconstruction is a reliable and anatomically restorative technique when direct tendon repair is not feasible. We evaluated the outcomes of EPL tendon reconstruction using palmaris longus tendon graft in patients following tendon rupture secondary to hardware impingement. Materials and Methods : This retrospective study was conducted on 20 patients at our institute from January 2020 to December 2024. Patients with EPL tendon rupture following fixation of forearm or distal radius fractures using plates, screws, K-wires, or intramedullary nails were included in the study. Surgical treatment included implant removal, debridement of tendon, and EPL reconstruction using ipsilateral palmaris longus tendon graft. Results : Reconstruction using palmaris longus tendon graft provided satisfactory restoration of thumb extension, grip strength, and hand function. 5 patients had extensor lag that recovered 4 months postoperatively. The TAM-ASSH grade at 6 months follow up were excellent in 15 patients and good in 5 patients. Conclusion : EPL tendon rupture is a preventable complication of osteosynthesis. Careful implant positioning, avoidance of dorsal cortical penetration, and recognition of tendon irritation are preventive measures. Palmaris longus tendon graft reconstruction provides reliable functional recovery with minimal donor morbidity.

Authors

Publication Details

Journal
Indian Journal of Orthopaedics Surgery
Published
2026-11-17
DOI
https://doi.org/10.18231/j.ijos.17843.1793601205
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Extensor pollicis longus tendon reconstruction with palmaris longus tendon graft due to attritional rupture by screws, K-wires, and intramedullary nails

Utkarsh Kailashnath Vishwakarma, Vidisha Sunil Kulkarni, Sunil Govind Kulkarni
3 links
Indian Journal of Orthopaedics Surgery
Orthopedic Surgery and Rehabilitation
article

Extensor pollicis longus tendon reconstruction with palmaris longus tendon graft due to attritional rupture by screws, K-wires, and intramedullary nails

Utkarsh Kailashnath Vishwakarma, Vidisha Sunil Kulkarni, Sunil Govind Kulkarni
article en

Abstract

Introduction : Extensor pollicis longus (EPL) tendon rupture is a significant complication following fracture fixation around the distal radius and forearm. The tendon is particularly susceptible to attritional wear caused by prominent screws, protruding Kirschner wires (K-wires), dorsal cortical penetration, and prominent intramedullary nail entry points. Rupture results in profound loss of thumb extension, reduced pinch strength, impaired dexterity, and functional disability. Palmaris longus (PL) tendon graft reconstruction is a reliable and anatomically restorative technique when direct tendon repair is not feasible. We evaluated the outcomes of EPL tendon reconstruction using palmaris longus tendon graft in patients following tendon rupture secondary to hardware impingement. Materials and Methods : This retrospective study was conducted on 20 patients at our institute from January 2020 to December 2024. Patients with EPL tendon rupture following fixation of forearm or distal radius fractures using plates, screws, K-wires, or intramedullary nails were included in the study. Surgical treatment included implant removal, debridement of tendon, and EPL reconstruction using ipsilateral palmaris longus tendon graft. Results : Reconstruction using palmaris longus tendon graft provided satisfactory restoration of thumb extension, grip strength, and hand function. 5 patients had extensor lag that recovered 4 months postoperatively. The TAM-ASSH grade at 6 months follow up were excellent in 15 patients and good in 5 patients. Conclusion : EPL tendon rupture is a preventable complication of osteosynthesis. Careful implant positioning, avoidance of dorsal cortical penetration, and recognition of tendon irritation are preventive measures. Palmaris longus tendon graft reconstruction provides reliable functional recovery with minimal donor morbidity.

Indian Journal of Orthopaedics SurgeryVol. 12(4)
Good health and well-being
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon