The Hinode EIS Active-Region Loop: A Density, Filling-Factor and Thermal-Energy Budget from Iron Line Ratios

The Extreme-ultraviolet Imaging Spectrometer on Hinode measures active-region loop densities directly, from the ratio of two iron twelve lines that depends on density and little else. Those densities, near three times ten to the ninth per cm3, can be combined with the observed loop width and emission measure to budget the loop. This paper does so for a representative active-region loop. The measured density predicts an emission measure larger than observed, giving a filling factor of 0.22. The loop holds 3.9e+26 erg of thermal energy and cools conductively in 5.49e+03 seconds. Supplying the whole active region at the published rate needs 9.55e+03 such loops. The filling factor below unity says the loop is structured, not filled, and that structure is part of the heating story.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-17
DOI
https://doi.org/10.5281/zenodo.24299415
Primary Topic
Solar and Space Plasma Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The Hinode EIS Active-Region Loop: A Density, Filling-Factor and Thermal-Energy Budget from Iron Line Ratios

William Alexander Aldred
2 links
Zenodo (CERN European Organization for Nuclear Research)
Solar and Space Plasma Dynamics
article

The Hinode EIS Active-Region Loop: A Density, Filling-Factor and Thermal-Energy Budget from Iron Line Ratios

William Alexander Aldred
article en

Abstract

The Extreme-ultraviolet Imaging Spectrometer on Hinode measures active-region loop densities directly, from the ratio of two iron twelve lines that depends on density and little else. Those densities, near three times ten to the ninth per cm3, can be combined with the observed loop width and emission measure to budget the loop. This paper does so for a representative active-region loop. The measured density predicts an emission measure larger than observed, giving a filling factor of 0.22. The loop holds 3.9e+26 erg of thermal energy and cools conductively in 5.49e+03 seconds. Supplying the whole active region at the published rate needs 9.55e+03 such loops. The filling factor below unity says the loop is structured, not filled, and that structure is part of the heating story.

Zenodo (CERN European Organization for Nuclear Research)
Solar and Space Plasma Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon