Passive Solar Heat Recovery from Building Surfaces for Boiler Feedwater Preheating

Large glazed building facades present an underutilised opportunity for thermal recovery in institutional settings. This study investigates the feasibility of embedding serpentine polycarbonate tubing within a double-glazed glass pane attached to the North and West-facing facade of the J03 Electrical Engineering Building at the University of Sydney (USYD) to preheat boiler feedwater to 35°C. The north facade, comprising 1,260 m² and accounting for 77% of total heat gain, receives solar irradiance during daylight, while the west facade contributes an additional 525 m². At a 1 kg/s flow rate, the system recovers 1.035 GWh/year with peak irradiance of 6.25 kWh/m²/day in summer. Over a 30-year lifespan, the system yields an NPV of $437,000, while mitigating 27.31 tonnes of CO₂ annually. Results suggest passive solar facade integration is a scalable, low-maintenance complement to existing institutional boiler infrastructure.

Publication Details

Journal
The Sydney Journal of Interdisciplinary Engineering
Published
2026-11-18
DOI
https://doi.org/10.30722/4y6qgs98
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Passive Solar Heat Recovery from Building Surfaces for Boiler Feedwater Preheating

The Sydney Journal of Interdisciplinary Engineering
Solar Energy Systems and Technologies
article

Passive Solar Heat Recovery from Building Surfaces for Boiler Feedwater Preheating

article en

Abstract

Large glazed building facades present an underutilised opportunity for thermal recovery in institutional settings. This study investigates the feasibility of embedding serpentine polycarbonate tubing within a double-glazed glass pane attached to the North and West-facing facade of the J03 Electrical Engineering Building at the University of Sydney (USYD) to preheat boiler feedwater to 35°C. The north facade, comprising 1,260 m² and accounting for 77% of total heat gain, receives solar irradiance during daylight, while the west facade contributes an additional 525 m². At a 1 kg/s flow rate, the system recovers 1.035 GWh/year with peak irradiance of 6.25 kWh/m²/day in summer. Over a 30-year lifespan, the system yields an NPV of $437,000, while mitigating 27.31 tonnes of CO₂ annually. Results suggest passive solar facade integration is a scalable, low-maintenance complement to existing institutional boiler infrastructure.

The Sydney Journal of Interdisciplinary EngineeringVol. 2(1)
Climate action, Affordable and clean energy, Responsible consumption and production, Sustainable cities and communities
Solar Energy Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon