Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis

Introduction Personalized optical simulation and machine learning provide a computational approach to estimating spectacle prescriptions for pediatric astigmatism. Methods This single-center, prospective, within-subject agreement study with randomized examination order evaluated prescriptions for 77 right eyes at a post-cycloplegia follow-up visit. The model used structured numerical wavefront exports and patient information for individualized optical reconstruction, virtual lens simulation, and clinical prescription residual calibration, and was developed using a separate dataset of 5,630 eyes. Artificial intelligence (AI) estimates and conventional autorefraction were compared with subjective refraction performed by an experienced optometrist masked to AI outputs. Children and the trial-lens outcome assessor were masked to prescription source, and lens presentation order was randomized. Agreement was evaluated for spherical equivalent (SE), J0, and J45. Inferential analyses were exploratory, without adjustment for multiple comparisons. Results SE mean bias ± standard deviation of paired differences was 0.01 ± 0.48 D for AI and 0.22 ± 0.57 D for conventional autorefraction; conventional Bland-Altman limits of agreement were −0.94 to 0.96 D and −0.89 to 1.33 D, respectively. The between-method difference in signed bias was −0.21 D (95% confidence interval: −0.35 to −0.07; P = 0.004). SE mean absolute errors were 0.30 D and 0.39 D, with a paired difference of −0.09 D (95% bootstrap confidence interval: −0.23 to 0.04). Astigmatic error analyses did not establish an overall advantage for AI. In the immediate comparison, trial-lens logMAR visual acuity was lower with AI, and 66.2% of participants preferred the AI prescription. Discussion A smaller SE mean bias does not establish greater individual accuracy, clinical interchangeability, or the effectiveness of AI-assisted clinical decision-making. Long-term benefits and safety during spectacle wear require further evaluation.

Authors

Institutions

Publication Details

Journal
Frontiers in Digital Health
Published
2026-11-17
DOI
https://doi.org/10.3389/fdgth.2026.1920169
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis

甄毅, Hong Chang, Jie Gao, Yan Huang
3 links
Frontiers in Digital Health
Ophthalmology and Visual Impairment Studies
article

Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis

甄毅, Hong Chang, Jie Gao, Yan Huang
article en

Abstract

Introduction Personalized optical simulation and machine learning provide a computational approach to estimating spectacle prescriptions for pediatric astigmatism. Methods This single-center, prospective, within-subject agreement study with randomized examination order evaluated prescriptions for 77 right eyes at a post-cycloplegia follow-up visit. The model used structured numerical wavefront exports and patient information for individualized optical reconstruction, virtual lens simulation, and clinical prescription residual calibration, and was developed using a separate dataset of 5,630 eyes. Artificial intelligence (AI) estimates and conventional autorefraction were compared with subjective refraction performed by an experienced optometrist masked to AI outputs. Children and the trial-lens outcome assessor were masked to prescription source, and lens presentation order was randomized. Agreement was evaluated for spherical equivalent (SE), J0, and J45. Inferential analyses were exploratory, without adjustment for multiple comparisons. Results SE mean bias ± standard deviation of paired differences was 0.01 ± 0.48 D for AI and 0.22 ± 0.57 D for conventional autorefraction; conventional Bland-Altman limits of agreement were −0.94 to 0.96 D and −0.89 to 1.33 D, respectively. The between-method difference in signed bias was −0.21 D (95% confidence interval: −0.35 to −0.07; P = 0.004). SE mean absolute errors were 0.30 D and 0.39 D, with a paired difference of −0.09 D (95% bootstrap confidence interval: −0.23 to 0.04). Astigmatic error analyses did not establish an overall advantage for AI. In the immediate comparison, trial-lens logMAR visual acuity was lower with AI, and 66.2% of participants preferred the AI prescription. Discussion A smaller SE mean bias does not establish greater individual accuracy, clinical interchangeability, or the effectiveness of AI-assisted clinical decision-making. Long-term benefits and safety during spectacle wear require further evaluation.

Frontiers in Digital HealthVol. 8
Beijing Tongren Hospital (CN), Ministry of Education of the People's Republic of China (CN), Capital Medical University (CN), He Eye Hospital (CN)
Good health and well-being
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon