Translational Evaluation of an Intelligent Bipolar Electrosurgical System with Integrated Neurostimulation for IONM

Abstract Background Frequent manual instrument exchanges between bipolar coagulators and neural probes compromise surgical workflow and elevate iatrogenic nerve injury risks. Especially, in robot-assisted surgery, the lack of an auxiliary robotic arm to hold dedicated probes further precludes real-time neural mapping. Consequently, integrating both electrocoagulation and neural stimulation into a single, unified instrument tip addresses an urgent clinical need to enable seamless intraoperative neuromonitoring without sacrificing surgical dexterity. Methods This comparative study engineered a parallel-connected isolation transformer topology (E-VTMS) for autonomous electrocoagulation-neurostimulation switching. In vitro efficiency testing (5–70 W) was followed by in vivo signal fidelity and thermal safety evaluations, comparing E-VTMS-driven forceps against gold-standard commercial probes in rodent sciatic and porcine recurrent laryngeal nerve models. Electrophysiological non-inferiority was quantified via paired t-tests. Results In vitro testing demonstrated > 98% energy efficiency (4.4 W vs. 4.5 W at 5 W baseline, 69.2 W vs 69.8W at 70W baseline). In vivo trials confirmed diagnostic non-inferiority, eliciting neural signals indistinguishable from gold-standard commercial probes (paired t-test; sciatic nerve: P = 0.286; recurrent laryngeal nerve: P = 0.806). Post-30W activation, saline irrigation and tissue contact rapidly cooled tips below the 42°C neural threshold (decay rates: 37.25°C/s and 11.56°C/s). Combined with 0 mA open-circuit leakage, these boundaries eliminate iatrogenic injury. Conclusions The E-VTMS platform integrates clinical IONM and electrosurgery into a single shared bipolar end-effector. This automated bimodal design eliminates manual instrument exchanges, optimizing surgical workflow and mitigating iatrogenic risks. Rigorously validated for thermal safety and electrophysiological fidelity, the technology demonstrates robust readiness for human clinical translation.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11013958/v1
Primary Topic
Intraoperative Neuromonitoring and Anesthetic Effects
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Translational Evaluation of an Intelligent Bipolar Electrosurgical System with Integrated Neurostimulation for IONM

高慧照, Liang Dai, Liang Chen, Rongqing Xu et al.
Research Square
Intraoperative Neuromonitoring and Anesthetic Effects
preprint

Translational Evaluation of an Intelligent Bipolar Electrosurgical System with Integrated Neurostimulation for IONM

高慧照, Liang Dai, Liang Chen, Rongqing Xu, Jiaxue Qi, Yueqiao Wang
preprint en

Abstract

Abstract Background Frequent manual instrument exchanges between bipolar coagulators and neural probes compromise surgical workflow and elevate iatrogenic nerve injury risks. Especially, in robot-assisted surgery, the lack of an auxiliary robotic arm to hold dedicated probes further precludes real-time neural mapping. Consequently, integrating both electrocoagulation and neural stimulation into a single, unified instrument tip addresses an urgent clinical need to enable seamless intraoperative neuromonitoring without sacrificing surgical dexterity. Methods This comparative study engineered a parallel-connected isolation transformer topology (E-VTMS) for autonomous electrocoagulation-neurostimulation switching. In vitro efficiency testing (5–70 W) was followed by in vivo signal fidelity and thermal safety evaluations, comparing E-VTMS-driven forceps against gold-standard commercial probes in rodent sciatic and porcine recurrent laryngeal nerve models. Electrophysiological non-inferiority was quantified via paired t-tests. Results In vitro testing demonstrated > 98% energy efficiency (4.4 W vs. 4.5 W at 5 W baseline, 69.2 W vs 69.8W at 70W baseline). In vivo trials confirmed diagnostic non-inferiority, eliciting neural signals indistinguishable from gold-standard commercial probes (paired t-test; sciatic nerve: P = 0.286; recurrent laryngeal nerve: P = 0.806). Post-30W activation, saline irrigation and tissue contact rapidly cooled tips below the 42°C neural threshold (decay rates: 37.25°C/s and 11.56°C/s). Combined with 0 mA open-circuit leakage, these boundaries eliminate iatrogenic injury. Conclusions The E-VTMS platform integrates clinical IONM and electrosurgery into a single shared bipolar end-effector. This automated bimodal design eliminates manual instrument exchanges, optimizing surgical workflow and mitigating iatrogenic risks. Rigorously validated for thermal safety and electrophysiological fidelity, the technology demonstrates robust readiness for human clinical translation.

Research Square
Nanjing University of Posts and Telecommunications (CN), Peking University Cancer Hospital (CN)
Good health and well-being
Intraoperative Neuromonitoring and Anesthetic Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon