Bond behavior between concrete and thermoplastic GFRP rebars with different diameters and surface geometries

This study investigates the bond behavior between concrete and novel thermoplastic Glass Fiber-Reinforced Polymer (TP-GFRP) reinforcing bars (rebars), manufactured using an Elium® acrylic thermoplastic matrix. Pull-out tests were performed on concrete specimens reinforced with TP-GFRP rebars from different manufacturers with three surface finishes: ribs, textured fabric, and a periodic pattern of pointed indentations. The influence of rebar diameter, surface geometry and concrete–rebar interface stiffness on bond strength and post-peak response was examined. Bond performance was also compared with that of reference rebars (ribbed steel and thermosetting GFRP) and with the AFGC threshold. Except for one prototype series, the bond strength of the TP-GFRP rebars exceeded the AFGC minimum value of 7.6 MPa (an indicative comparison given the test conditions used) and was comparable to or higher than that of the thermosetting GFRP reference, while remaining lower than that of steel. Moreover, surface geometry was found to play a major role: among rebars of approximately 12 mm diameter, ribbed geometries provided the highest bond strength, whereas textured fabric finishes exhibited the most stable post-peak behavior. Bond strength was also correlated with the geometric characteristics of the surface features, particularly the concrete lug ratio and the relative rib height. In addition, several pull-out specimens were instrumented with Distributed Fiber-Optic Sensing (DFOS) cables to measure local strain profiles along the concrete–rebar interface. A parametric inverse method, based on the mechanical transfer function (MTF) of the cable, was proposed to correct the raw strain profiles for the strain-lag effect induced by the cable coating and the adhesive layer. The corrected strain profiles were finally used to assess the development length of the various TP-GFRP rebars at a low load level. Ribbed rebars exhibited the largest development lengths, suggesting a more extended distribution of shear stresses along the interface.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2026-11-17
DOI
https://doi.org/10.1016/j.conbuildmat.2026.148924
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Bond behavior between concrete and thermoplastic GFRP rebars with different diameters and surface geometries

Marc Quiertant, Sylvain Chataigner, Xavier Chapeleau, Karim Benzarti et al.
1 links
Construction and Building Materials
Structural Behavior of Reinforced Concrete
article

Bond behavior between concrete and thermoplastic GFRP rebars with different diameters and surface geometries

Marc Quiertant, Sylvain Chataigner, Xavier Chapeleau, Karim Benzarti, Ludwig Battais, Jean-Marie Hénault, Arnaud Rolland, Maha Fodda
article en

Abstract

This study investigates the bond behavior between concrete and novel thermoplastic Glass Fiber-Reinforced Polymer (TP-GFRP) reinforcing bars (rebars), manufactured using an Elium® acrylic thermoplastic matrix. Pull-out tests were performed on concrete specimens reinforced with TP-GFRP rebars from different manufacturers with three surface finishes: ribs, textured fabric, and a periodic pattern of pointed indentations. The influence of rebar diameter, surface geometry and concrete–rebar interface stiffness on bond strength and post-peak response was examined. Bond performance was also compared with that of reference rebars (ribbed steel and thermosetting GFRP) and with the AFGC threshold. Except for one prototype series, the bond strength of the TP-GFRP rebars exceeded the AFGC minimum value of 7.6 MPa (an indicative comparison given the test conditions used) and was comparable to or higher than that of the thermosetting GFRP reference, while remaining lower than that of steel. Moreover, surface geometry was found to play a major role: among rebars of approximately 12 mm diameter, ribbed geometries provided the highest bond strength, whereas textured fabric finishes exhibited the most stable post-peak behavior. Bond strength was also correlated with the geometric characteristics of the surface features, particularly the concrete lug ratio and the relative rib height. In addition, several pull-out specimens were instrumented with Distributed Fiber-Optic Sensing (DFOS) cables to measure local strain profiles along the concrete–rebar interface. A parametric inverse method, based on the mechanical transfer function (MTF) of the cable, was proposed to correct the raw strain profiles for the strain-lag effect induced by the cable coating and the adhesive layer. The corrected strain profiles were finally used to assess the development length of the various TP-GFRP rebars at a low load level. Ribbed rebars exhibited the largest development lengths, suggesting a more extended distribution of shear stresses along the interface.

Construction and Building MaterialsVol. 551
Centre National de la Recherche Scientifique (FR), Laboratoire Navier (FR), École Supérieure d'Ingénieurs des Travaux de la Construction de Cachan (FR), Électricité de France (France) (FR), Université Gustave Eiffel (FR), Centre d'Études et d'Expertise sur les Risques, l'Environnement, la Mobilité et l'Aménagement (FR)
Industry, innovation and infrastructure
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon