Numerical investigation of rib-angle and rib-height effects on secondary flow structure and thermohydraulic performance in double-sided V-shaped rib microchannel heat sinks

Previous V-rib studies have not systematically resolved how reversal of the V-opening direction across 90° interacts with rib height and Reynolds number in an aligned double-sided equal-branch configuration. To address this gap, three-dimensional conjugate heat transfer simulations were conducted for 225 microchannel configurations with aligned double-sided V-shaped ribs (DSVRs) over 30° ≤ θ ≤ 150°, 0.015 mm ≤ H r ≤ 0.035 mm, and 100 ≤ Re ≤ 900. Equal-branch V-ribs were positioned at corresponding locations on the opposing walls to examine acute-to-obtuse rib orientations. Among the investigated angles, θ = 30° generated the strongest secondary flow; outwardly directed streamwise vortices promoted cross-sectional fluid redistribution and thermal-boundary-layer disruption. At obtuse angles, the rib-guided flow converged toward the centerline and reversed the vortex rotation direction. Increasing H r strengthened the secondary flow and increased Nu , but also intensified blockage and frictional loss. The highest computed PEC at each investigated Re occurred at θ = 30°, with corresponding rib heights of H r = 0.035 mm at Re = 100 and 300, H r = 0.030 mm at Re = 500, and H r = 0.025 mm at Re = 700 and 900. The highest computed PEC among all investigated cases was 2.0273 at Re = 500, θ = 30°, and H r = 0.030 mm. Empirical correlations in a modified power-law form were developed for f and Nu at θ = 30° and 150°, with R 2 values of 0.9718–0.9964 and MAPE values of 2.11%–5.72%.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-11-17
DOI
https://doi.org/10.1016/j.tsep.2026.105010
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical investigation of rib-angle and rib-height effects on secondary flow structure and thermohydraulic performance in double-sided V-shaped rib microchannel heat sinks

Yong Gap Park, Hoon Ki Choi, Young Min Seo, Mun Su Lee et al.
4 links
Thermal Science and Engineering Progress
Heat Transfer and Optimization
article

Numerical investigation of rib-angle and rib-height effects on secondary flow structure and thermohydraulic performance in double-sided V-shaped rib microchannel heat sinks

Yong Gap Park, Hoon Ki Choi, Young Min Seo, Mun Su Lee, Chan Woo An
article en

Abstract

Previous V-rib studies have not systematically resolved how reversal of the V-opening direction across 90° interacts with rib height and Reynolds number in an aligned double-sided equal-branch configuration. To address this gap, three-dimensional conjugate heat transfer simulations were conducted for 225 microchannel configurations with aligned double-sided V-shaped ribs (DSVRs) over 30° ≤ θ ≤ 150°, 0.015 mm ≤ H r ≤ 0.035 mm, and 100 ≤ Re ≤ 900. Equal-branch V-ribs were positioned at corresponding locations on the opposing walls to examine acute-to-obtuse rib orientations. Among the investigated angles, θ = 30° generated the strongest secondary flow; outwardly directed streamwise vortices promoted cross-sectional fluid redistribution and thermal-boundary-layer disruption. At obtuse angles, the rib-guided flow converged toward the centerline and reversed the vortex rotation direction. Increasing H r strengthened the secondary flow and increased Nu , but also intensified blockage and frictional loss. The highest computed PEC at each investigated Re occurred at θ = 30°, with corresponding rib heights of H r = 0.035 mm at Re = 100 and 300, H r = 0.030 mm at Re = 500, and H r = 0.025 mm at Re = 700 and 900. The highest computed PEC among all investigated cases was 2.0273 at Re = 500, θ = 30°, and H r = 0.030 mm. Empirical correlations in a modified power-law form were developed for f and Nu at θ = 30° and 150°, with R 2 values of 0.9718–0.9964 and MAPE values of 2.11%–5.72%.

Thermal Science and Engineering ProgressVol. 80
Changwon National University (KR), Korea Electrotechnology Research Institute (KR), Korea University of Science and Technology (KR)
Ministry of Education, National Research Foundation of Korea, Ministry of Education, India, Ministry of Science and ICT, South Korea
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon