Association of treponemal chemiluminescent immunoassay signal intensity with TPPA reactivity in reverse sequence syphilis screening
ABSTRACT Reverse sequence screening for syphilis using treponemal chemiluminescent immunoassays (Tp-CIAs) is widely used in clinical laboratories; however, interpretation is typically based on binary cutoff values, and the clinical value of signal intensity remains underutilized. We conducted a retrospective diagnostic performance accuracy study including 1,827 individuals undergoing routine screening to evaluate the clinical utility of the Tp-CIA cutoff index (COI) as a continuous variable, using the TPPA as the reference standard. ROC analysis was performed to determine the optimal cutoff, and associations between COI values and TPPA reactivity were assessed. Tp-CIA demonstrated excellent discrimination of TPPA reactivity (area under the curve 0.992). COI values showed a strong monotonic association with TPPA reactivity (Spearman r s = 0.855), increasing from 2.5% at a COI <1 to 99.8% at a COI ≥30. An exploratory cutoff of COI = 3.25 increased specificity from 88.6% to 96.4%, with a corresponding decrease in sensitivity from 99.1% to 95.9%, compared with the manufacturer-recommended cutoff of 1.0. Discordant results (3.9%) were largely confined to low COI values, whereas high COI values were strongly associated with TPPA reactivity. Diagnostic performance remained consistent across HIV subgroups. Among individuals with concurrent non-treponemal testing, COI values were positively correlated with ordered rapid plasma reagin ( r s = 0.637) and toluidine red unheated serum test ( r s = 0.705) titer levels. These findings demonstrate that, within the analytical conditions of this study, higher assay-specific COI values were associated with a greater likelihood of TPPA reactivity. COI-based interpretation should remain supplementary to established confirmatory testing and clinical assessment; exploratory threshold requires independent analytical and clinical validation. IMPORTANCE Syphilis remains a growing global public health concern, and reverse sequence screening using Treponema pallidum chemiluminescent immunoassay (Tp-CIA) is widely adopted. Although these assays are interpreted qualitatively using manufacturer-defined cutoffs, the underlying signal intensity varies across specimens. In this study cohort, increasing Tp-CIA cutoff index (COI) values were associated with an increasing observed proportion of TPPA-reactive results. This association was assay- and cohort-specific and should be interpreted descriptively. COI should not replace established confirmatory testing, quantitative non-treponemal testing, or clinical assessment, and its potential supplementary value requires independent analytical and clinical validation.
Authors
- Yanhua Yu (ORCID: https://orcid.org/0009-0004-9916-5354)
- Jinli Lou (ORCID: https://orcid.org/0000-0001-9855-7904)
- 田树萍 (ORCID: https://orcid.org/0009-0004-4167-8376)
- JIANG Feifei
- Yu Li (ORCID: https://orcid.org/0009-0004-7960-6845)
- 冯霞 (ORCID: https://orcid.org/0000-0002-8072-4441)
- Hui Liu (ORCID: https://orcid.org/0009-0005-4955-6063)
- Yuhan Duan
- Xin Liu (ORCID: https://orcid.org/0000-0003-0050-827X)
- Shujing Huang (ORCID: https://orcid.org/0009-0002-8020-4398)
Institutions
- Capital Medical University (CN)
- The Central Hospital of Enshi Tujia and Miao Autonomous Prefecture (CN)
- Beijing YouAn Hospital (CN)
- Shandong First Medical University (CN)
Publication Details
- Journal
- Microbiology Spectrum
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1128/spectrum.01501-26
- Primary Topic
- Syphilis Diagnosis and Treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00