Microfluidic Biosensing and Data-Driven Surveillance of Fish Pathogens in Marine Ranching: Capabilities, Validation Gaps and Deployment Barriers

Marine ranches are open ecological-production integrated systems, and as intensive coastal aquaculture expands, the threat of pathogenic diseases is increasingly severe. Pathogen monitoring in these environments faces three major practical challenges: dispersed sampling, low pathogen loads, and strong environmental interference (high salinity, high turbidity, and high organic content), which limit the effectiveness of conventional laboratory methods. This review therefore explores the potential and bottlenecks of microfluidic biosensing technologies for in situ pathogen monitoring in marine ranches. Using a structured literature search and title/abstract evidence mapping, we summarize recent advances in pathogen characteristics, continuous-flow/droplet/digital microfluidic platforms, and AI-based early warning systems. A complementary bibliometric scan of the Web of Science Core Collection (44,892 records) tracks publication growth in this field. Comparisons between reported environmental pathogen concentrations (e.g., culturable Vibrio communities at 103–105 CFU·mL−1 in production water) and analytical sensitivity in buffer (<1 copy/μL) show that buffer LOD alone is insufficient to establish field applicability. The key bottlenecks include matrix tolerance, sample-processing throughput, and validation depth. Among the 20 evaluated platforms, two reported on-site or field demonstrations, but neither constitutes multi-center prospective diagnostic validation. Consequently, four key deployment barriers for microfluidic monitoring in marine ranch settings can be identified: (1) mismatch between sampling volume and chip interface; (2) matrix inhibition affecting quantitative accuracy; (3) difficulty in distinguishing pathogen viability states; and (4) failure of mechanisms such as electrowetting in seawater. To address these issues, this paper proposes a three-step implementation pathway: developing validated multiplex detection panels; launching regional early-warning pilot projects; and finally, establishing a data-driven closed-loop monitoring ecosystem. The case study focuses on the South China Sea, while the framework is applicable to warm-water regions worldwide.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-11-16
DOI
https://doi.org/10.3390/bios16110656
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Microfluidic Biosensing and Data-Driven Surveillance of Fish Pathogens in Marine Ranching: Capabilities, Validation Gaps and Deployment Barriers

Xianzhang Wang, Ran Peng, Jin Yan, Wei Wang et al.
Biosensors
Biosensors and Analytical Detection
article

Microfluidic Biosensing and Data-Driven Surveillance of Fish Pathogens in Marine Ranching: Capabilities, Validation Gaps and Deployment Barriers

Xianzhang Wang, Ran Peng, Jin Yan, Wei Wang, Yuezhu Wang, Yishan Lu
article en

Abstract

Marine ranches are open ecological-production integrated systems, and as intensive coastal aquaculture expands, the threat of pathogenic diseases is increasingly severe. Pathogen monitoring in these environments faces three major practical challenges: dispersed sampling, low pathogen loads, and strong environmental interference (high salinity, high turbidity, and high organic content), which limit the effectiveness of conventional laboratory methods. This review therefore explores the potential and bottlenecks of microfluidic biosensing technologies for in situ pathogen monitoring in marine ranches. Using a structured literature search and title/abstract evidence mapping, we summarize recent advances in pathogen characteristics, continuous-flow/droplet/digital microfluidic platforms, and AI-based early warning systems. A complementary bibliometric scan of the Web of Science Core Collection (44,892 records) tracks publication growth in this field. Comparisons between reported environmental pathogen concentrations (e.g., culturable Vibrio communities at 103–105 CFU·mL−1 in production water) and analytical sensitivity in buffer (<1 copy/μL) show that buffer LOD alone is insufficient to establish field applicability. The key bottlenecks include matrix tolerance, sample-processing throughput, and validation depth. Among the 20 evaluated platforms, two reported on-site or field demonstrations, but neither constitutes multi-center prospective diagnostic validation. Consequently, four key deployment barriers for microfluidic monitoring in marine ranch settings can be identified: (1) mismatch between sampling volume and chip interface; (2) matrix inhibition affecting quantitative accuracy; (3) difficulty in distinguishing pathogen viability states; and (4) failure of mechanisms such as electrowetting in seawater. To address these issues, this paper proposes a three-step implementation pathway: developing validated multiplex detection panels; launching regional early-warning pilot projects; and finally, establishing a data-driven closed-loop monitoring ecosystem. The case study focuses on the South China Sea, while the framework is applicable to warm-water regions worldwide.

BiosensorsVol. 16(11)
Dalian Maritime University (CN), Guangdong Ocean University (CN)
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon